Setting The System Ip Address As The Source Address; Configuring Individual Radius Servers - 3Com 3CRWX120695A, 3CRWX440095A Configuration Manual

Wireless lan switch and controller
Table of Contents

Advertisement

Configuring RADIUS Servers
347
To reset global RADIUS server settings to their factory defaults, use the
following command:
clear radius {deadtime | key | retransmit | timeout}
For example, the following command resets the dead-time timer to
0 minutes on all RADIUS servers in the WX configuration:
WX1200# clear radius deadtime
success: change accepted.
Setting the System IP
By default, RADIUS packets leaving the WX switch have the source IP
Address as the Source
address of the outbound interface on the switch. This source address can
Address
change when routing conditions change. If you have set a system IP
address for the WX switch, you can use it as a permanent source address
for the RADIUS packets sent by the switch.
To set the WX system IP address as the address of the RADIUS client, type
the following command:
WX1200# set radius client system-ip
success: change accepted.
To remove the WX switch's system IP address from use as the source
address in RADIUS client requests from the switch to its RADIUS server(s),
type the following command:
WX1200# clear radius client system-ip
success: change accepted.
The command causes the WX to select a source interface address based
on information in its routing table as the RADIUS client address.
Configuring
You must set up a name and IP address for each RADIUS server. To
Individual RADIUS
configure a RADIUS server, use the following command:
Servers
set radius server server-name [address ip-address]
[key string]
The server name must be unique for this RADIUS server on this WX
switch. The key (password) string is the shared secret that the WX switch
uses to authenticate itself to the RADIUS server. Do not use the same
name for a RADIUS server and a RADIUS server group.

Advertisement