PRIMERGY BX600 S3 Hardware Manual page 94

Blade server system
Table of Contents

Advertisement

Chapter 5 CLI
9. NIC Status Detection (1_3_9)
Sets NIC status detection.
+--------------------------------------------+
|
+--------------------------------------------+
(1) NIC Status Detection
(2) NIC Detection Timeout : 120
Enter selection or type (0) to quit:
❑: Parameter
Parameter
1. NIC Status Detection
94
NIC Status Detection
: disable
Setting
enable
Sets whether to detect NIC status or not when the
disable
Management Blade is redundantly configured.
If this setting is enabled, communication is monitored on
a steady basis via the LAN interface. If communication
does not take place for a given amount of time (2. NIC
Detection Timeout) performs a NIC status self
diagnostic test. If an error is detected, the master is
forcibly switched and the communication path is
changed. Not only this but management and operation
can also be continued via the LAN interface even if a
communication failure caused by NIC error or LAN
cable disconnection occurs.
Note:
When Management Blade is non redundantly configured, it is
necessary to set "NIC Status Detection" to "disable".
When Management Blade is redundantly configured and "NIC
Status Detection" is set to "enable" always check the following in
advance.
• Connect the LAN cable to the master and slave Management
Blades. Check that the link between this and the connection
destination network device has been established.
• Check that both the master and slave Management Blade of the
monitoring terminal have a network configuration that enables
communication using LAN interface.
|
page_1_3_9
Contents

Advertisement

Table of Contents
loading

Table of Contents