Chapter 2 Installing and Removing Management Blades
4
Perform LAN interface settings by clicking on [System Property] – [LAN
Interface] in the setting parameter menu of the displayed Management Blade
initial screen in this order.
For details about setting methods, refer to "● LAN Interface" ( p.29).
■ Serial Interface Settings
1
Connect the management terminal to the Management Blade using the
attached RS-232C cross cable.
1. Connect an RS-232C cross cable to the Management Blade.
Connect the RS-232C cross cable connector to
the serial port on the Management Blade
operating in master mode.
2. Connect an RS-232C cross cable to the management terminal.
Connect the other end of the cable to the serial port on the management terminal.
2
Start the terminal software in the management terminal and perform settings to
enable Management Blade connection.
For details about setting methods, refer to "5.1.1 Using Serial Interface" ( p.64).
18
Connect the management terminal to the Management Blade operating in master
mode. It is not possible to connect to CLI from the serial port of the Management Blade
operating in slave mode. Check the operation mode of the Management Blade in the
Management Blade master display LED ( "1.2 Component Names and Functions"
(p.11)).