PRIMERGY TX200 S3 Service Supplement Manual

Hide thumbs Also See for TX200 S3:

Advertisement

Quick Links

PRIMERGY
PRIMERGY TX200 S3
Server
Service Supplement
Susanne Däschlein
Fujitsu Siemens Computers GmbH München
81730 München
e-mail: email: manuals@fujitsu-siemens.com
Tel.: (089) 61001155
Fax: (++49) 700 / 372 00000
TX200 S3
Sprachen: En
Edition July 2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TX200 S3 and is the answer not in the manual?

Questions and answers

Summary of Contents for PRIMERGY TX200 S3

  • Page 1 PRIMERGY PRIMERGY TX200 S3 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700 / 372 00000 TX200 S3 Sprachen: En Edition July 2006...
  • Page 2: Copyright And Trademarks

    Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Fax forms for sending us your comments are included in the back of the manual. There you will also find the addresses of the relevant User Documentation Department.
  • Page 3: Table Of Contents

    Index ........Service Supplement TX200 S3...
  • Page 5: Introduction

    Introduction The PRIMERGY TX200 S3 Server is an Intel-based server for medium-sized and large networks. The server is suitable for use as a file server as well as an application, information, or Internet server. It is available as a floorstand or rack model.
  • Page 6 Information about the system board: Technical Manual – Features of the system board – Board layout – Jumper settings – LED displays – SAS controller D2107 – Replacing the battery Table 1: Overview of the documentation TX200 S3 Service Supplement TX200 S3...
  • Page 7 – Replacing the adapter board for system fans – Replacing the intrusion switches – Replacing the IDTEMP Combo – Replacing the system board Board layout BIOS setup BIOS Setup Table 1: Overview of the documentation TX200 S3 Service Supplement TX200 S3...
  • Page 8: Notational Conventions

    Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. Table 2: Notational conventions Service Supplement TX200 S3...
  • Page 9: Procedure

    Ê Close the server. Ê Connect the cables. Ê Connect the server to the power outlet. Ê Start the operating system. Ê If necessary, configure the server as required. This procedures are described in the Operating Manual. Service Supplement TX200 S3...
  • Page 11: Safety Notes

    (public) power supply networks for the type A connector. The server automatically sets itself to a voltage in the range of 100 V to 240 V. Make sure that your local voltage is within this range. Service Supplement TX200 S3...
  • Page 12 (risk of electric shock or short circuit). In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign matter), switch off the device immediately, remove the power plug and contact your sales outlet or customer service team. Service Supplement TX200 S3...
  • Page 13 You may only set those resolutions and refresh rates specified in the „Technical data“ section of the monitor description. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service centre. Service Supplement TX200 S3...
  • Page 14 All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant: Cd Cadmium Hg Mercury Pb Lead Service Supplement TX200 S3...
  • Page 15 The CD-/DVD-ROM drive contains a laser diode (LED). Sometimes the LED produces a stronger laser beam than laser class 1. Direct view into this laser beam is dangerous. Never remove parts of the CD-/DVD-ROM drive assembly! Service Supplement TX200 S3...
  • Page 16 Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components. Place all components on a static-safe base. You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN 61340-5-1, ANSI/ESD S20.20). Service Supplement TX200 S3...
  • Page 17: Replacement Routines

    Preparation 4.1.1 Floorstand model You will find a detailed description of ’Opening the server’ and ’Removing the front cover’ in the Options Guide TX200 S3. 4.1.1.1 Opening the server Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off the server, press the on/off switch.
  • Page 18: Rack Model

    Rack model You will find a detailed description of ’Opening the server’ and ’Removing the rack front cover’ in the Options Guide TX200 S3. Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off the server, press the on/off button.
  • Page 19: Replacing The Operating Panel

    (see the board layout on page 47). Ê Now push the operating panel module fully into the upper bay of the drive cage. Ê Close the server and connect all power plugs (for a detailed description see the Options Guide). Service Supplement TX200 S3...
  • Page 20: Replacing The Floppy Disk Drive (Multibay)

    CD/DVD-ROM drive. Ê Remove the power cable at the rear side of the floppy disk drive. Ê Remove the floppy cable from the connector on the system board (see also the Technical Manual for the system board). Service Supplement TX200 S3...
  • Page 21 Ê Press the two metal tongues of the EasyClick rails inward (1) until the locking mechanism is released. Ê Pull the multibay unit out of the bay (2). Figure 5: Removing the EasyClick rails Ê Remove the two screws on each side and take the EasyClick rails away. Service Supplement TX200 S3...
  • Page 22: Replacing The Standard Fans

    Ê Press the two green touch points of the standard fans simultaneously in opposite directions and lift out the standard fans. Ê Install the new standard fans. Ê Close the server and connect all power plugs (for a detailed description see the Options Guide). Service Supplement TX200 S3...
  • Page 23: Replacing The Processor Fan Holder

    Ê Redundant fans: Remove the processor fan holder (see the section “Replacing the processor fan holder” on page 23). Ê Remove the guidance of the processor fan holder which is positioned at the PS separation plate. Service Supplement TX200 S3...
  • Page 24 Figure 7: Fastening screws for the power supply unit with adapter panel Ê Remove the four screws of the adapter panel and pull the power supply unit together with the adapter panel out of the server. Service Supplement TX200 S3...
  • Page 25 (four screws). Figure 9: Mounting the bracket onto the new power supply unit Ê Remove the mounting bracket from the defective power supply unit, and mount it onto the new power supply unit (two screws). Service Supplement TX200 S3...
  • Page 26 Ê Fasten the power supply unit with the adapter panel to the rear of the server (see figure 7 on page 24). Ê Close the server and connect all power plugs (for a detailed description see the Options Guide). Service Supplement TX200 S3...
  • Page 27: Replacing The Power Backplane

    Power backplane. Ê Remove the screw (see the circle) and take out the PS safe guard. Take care that the screw doesn’t fall inside the housing. Ê Disconnect all power cables from the Power backplane. Service Supplement TX200 S3...
  • Page 28 Ê Fasten the Power backplane with one screw in the PS cage. Ê Push the PS cage into the bay. Make sure that the noses of the PS cage engage in the chassis (for a detailed description see the Options Guide). Service Supplement TX200 S3...
  • Page 29: Replacing The Sas Backplane/Scsi Backplane

    “Preparation” on page Ê Remove all the hot-plug hard disk drives (for a description see the Operating Manual). CAUTION! Check if all hard disk drives are uniquely identified so that you can reinsert them into their original bays. Service Supplement TX200 S3...
  • Page 30 Ê Pull out the connectors of the I C cable, the power cable (2), and the two SAS cables (3) from the SAS backplane. CAUTION! Notice the connections of the two SAS cables. The plugs are labelled (MLC1 and MLC2). Service Supplement TX200 S3...
  • Page 31 Ê Press the latch of the plastic bar away from the backplane holder until the locking disengages. Ê Pull the plastic bar forward until the two hooks get out of the punched holes and remove the plastic bar. Service Supplement TX200 S3...
  • Page 32 Ê Push the backplane holder against the hard disk cage until the centering tabs (see the figure above) on the upper edge engage. Ê Fasten the backplane holder using the knurled screw. Service Supplement TX200 S3...
  • Page 33 C cable and place the cable in the cable clamp. Ê Reinstall all hot-plug hard disk drives in their former slots. Ê Close the server and connect all power plugs (for a detailed description see the Options Guide). Service Supplement TX200 S3...
  • Page 34: Replacing The Adapter Board For System Fans

    Ê Take out the two system fans positioned near to the hard disk cage. Screw Figure 17: Removing the fan holders Ê Loosen the captive screw of the two fan holders and take out the fan holders. Ê Disconnect the cable from the adapter board. Service Supplement TX200 S3...
  • Page 35 Ê Insert the two system fans in the two fan holders. Ê Reinstall the ventilation duct over the system fans. Ê Close the server and connect all power plugs (for a detailed description see the Options Guide). Service Supplement TX200 S3...
  • Page 36: Replacing The Intrusion Switches

    Ê Push the lock of the SCO hood guide to the right hand side using a screws driver (1). Ê Take out the SCO hood guide upward. Ê Remove the SAS or SCSI backplane holder as described in section “Replacing the SAS backplane/SCSI backplane” on page Service Supplement TX200 S3...
  • Page 37 Replacement routines Replacing the intrusion switches Figure 20: Removing screws and intrusion switches Ê Remove the two screws (see the circles). Ê Remove the two screws (see the arrows) and take out the intrusion switch downward. Service Supplement TX200 S3...
  • Page 38 Replacing the intrusion switches Replacement routines Figure 21: Removing the screws Ê Remove the six screws (see the circles). Ê Pull out the hard disk cage frontward. Service Supplement TX200 S3...
  • Page 39 Ê Route the intrusion switch cable. Lay the intrusion switch with the two wires over the server’s edge as shown in the figure above. Ê Position the intrusion switch with the three wires on the front cover and fasten it with two screws. Service Supplement TX200 S3...
  • Page 40 Ê Hook the SCO hood guide into the right hand side. Push it down until it engages on the left hand side (see circle). Ê Close the server and connect all power plugs (for a detailed description see the Options Guide). Service Supplement TX200 S3...
  • Page 41: Replacing The Idtemp Combo

    C cable. Ê Pull the I C cable out of the white cable clamps. Ê Remove the I C cable from the connector on the IDTEMP combo. Ê Remove the screw and take out the IDTEMP combo. Service Supplement TX200 S3...
  • Page 42: Replacing The System Board

    23). Ê Remove the heat sink holder, the heat sinks and the processors (for a description see the Options Guide). Ê Remove the memory modules (for a description see the Options Guide). Service Supplement TX200 S3...
  • Page 43 Ê Carefully lift the system board out of the chassis in a slight angle. Thereby you pull the connectors out of the connector panel. Service Supplement TX200 S3...
  • Page 44 23). Ê If removed before: Insert the RAID key (for a description see the Options Guide). Ê Install all controllers in their former slots (for a description see the Operating Manual and Options Guide). Service Supplement TX200 S3...
  • Page 45 If the customer owns a license key for Advanced Video Redirection and Remote Storage (iRMC Advanced Pack), the license key has to be loaded onto the iRMC via the iRMC web interface (description see manual „PRIMERGY ServerView Suite integrated Remote Management Controller“) after replacing the system board. Service Supplement...
  • Page 47: Appendix

    The board layout of the system board and the SAS controller D2107 is described in the Technical Manual of the system board D2109. 5.1.1 Operating panel board Part number: A3C40050401 Operating panel module assembled: C26361-K644-Z332 Connector USB cable Connector operating panel cable Connector I C cable Service Supplement TX200 S3...
  • Page 48: Sas Backplane 1-Channel

    Board layout Appendix 5.1.2 SAS backplane 1-channel Part number: A3C40071451 SAS backplane holder assembled: S26361-F2570-V440 Connector I C cable Connector power cable SAS connector channel A SAS connector channel B SAS connector for accessible SAS drives Service Supplement TX200 S3...
  • Page 49: Scsi Backplane 1-Channel

    Appendix Board layout 5.1.3 SCSI backplane 1-channel Part number: A3C40052611 SCSI backplane holder assembled: S26361-F2570-V420-R Connector SCSI cable Connector power cable Connector I C cable Service Supplement TX200 S3...
  • Page 50: Power Backplane

    Board layout Appendix 5.1.4 Power backplane Part number: A3C40064303 No. Xn connector Connector for cable T26139-Y3758-V8 / SNP:A3C40057456-R T26139-Y3952-V1 / SNP:A3C40064985 T26139-Y3952-V11 / SNP:A3C40064987 Service Supplement TX200 S3...
  • Page 51: Processor Fan Backplane

    Appendix Board layout 5.1.5 Processor fan backplane Part number: A3C40052691 Processor fan holder assembled: SNP:A3C40052691 Connector fan cable (T26139-Y3940-V1/SNP:A3C40057417-R) Service Supplement TX200 S3...
  • Page 52: Adapter Board For System Fans

    Board layout Appendix 5.1.6 Adapter board for system fans Part number: S26361-D1708-R12 Connector for cable T26139-Y2493-V8 / SNP:A3C40057454 Service Supplement TX200 S3...
  • Page 53: Index

    19, Power backplane 27, processor fan backplane processor fan holder 23, SAS backplane 29, SAS backplane holder SCSI backplane SCSI backplane holder standard fans standard PS Service Supplement TX200 S3...
  • Page 55 Comments Fujitsu Siemens Computers GmbH User Documentation Suggestions 81730 München Germany Corrections Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY TX200 S3 Server TX200 S3...
  • Page 57 Comments Fujitsu Siemens Computers GmbH User Documentation Suggestions 81730 München Germany Corrections Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY TX200 S3 Server TX200 S3...
  • Page 59 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Table of Contents