Chapter 5 CLI
❑: Parameter
Parameter
1. Set Boot Watchdog Time
2. Set Boot Watchdog Enable
3. Set Boot Watchdog Action
The "OS Boot Monitoring" function can also be enabled or disabled from ServerView.
If ServerView is not installed to the Server Blade, be sure to set "2. Set Boot Watchdog Enable" to
"disable". If the setting is "enable", there is a fear that this server may automatically turn off or restart
improperly.
Even when ServerView is installed to the Server Blade, if starting the system while the PRIMERGY
Startup Disc or floppy disks for activating hardware configuration tools is inside, be sure to disable
the "OS Boot Monitoring" function (default settings are invalid).
If you start up the system while the "OS Boot Monitoring" function remains effective, the operation of
the Server Blade may become unpredictable at such times as an abrupt power interruption or
restart. If the "OS Boot Monitoring" function is needed, it should be reset to enabled before resuming
normal server operation.
When setting this function, refer to "ServerView User's Guide" to fully learn about its specifications,
in order to set it correctly.
110
Setting
2minutes
Monitors OS boot failure according to the set time.
5minutes
10minutes
15minutes
20minutes
30minutes
60minutes
100minutes
enable
Specifies whether to monitor the OS boot or not.
disable
no-action
Sets Server Blade power supply. When using refer to
hard reset
"6.2 Points to Note about Remote Power OFF and the
off
Shutdown Function" ( p.139).
graceful
• no-action
shutdown and
No action is taken.
power-cycle
• hard reset
Reboots the Server Blade.
• off
Turn the Server Blade off.
• graceful shutdown and power-cycle
Turns power on again after turning off power and
shutting down the OS using the ServerView agent
operating on the Server Blade.