PRIMERGY BX600 S3 Hardware Manual page 33

Blade server system
Table of Contents

Advertisement

- Critical Event
Critical events are displayed. If the problem is not solved, it may cause an error in the operations of
the system.
All logs can be deleted by clicking [Clear All Entries].
When "Management Blade Wrap Around Event Log Enable" is set to "disable" in
Management Blade, if the number of event logs is maximized, no more event logs can be
recorded. Periodically check [Event Log] and save or delete logs as necessary.
Save them by copying the screen text.
• Alarm Handler
On the Alarm Handler page, the settings of alarm handler are checked. Alarm handler can set event
log operations when an event occurs within the system.
The Alarm Handler pages are explained below.
• Mail Settings (Not supported)
This is where mail settings are performed.
Display/Parameter
To
From
Host
Subject
Administrator Name
Phone number
• Error Forwarding
In this section, the filter for out going e-mails is set. In alarm handler, outgoing alarms can be
filtered by the alarm group and error level.
- Error Forwarding Level
Alarms which have lower level of importance than the specified level can be set to not be sent.
• Server Blade Power On/Off Event Log Enable
This is set whether power ON/OFF and shutdown of the Server Blade is recorded in a Management
Blade event log.
- enable
Event logs related power ON/OFF and shutdown of the Server Blade is recorded.
- disable
Event logs related power ON/OFF and shutdown of the Server Blade is not recorded.
If set to "enable", the number of event logs increases. Pay attention to the remaining
number of event logs, make sure not to exceed the maximum number of event logs or
set "Management Blade Wrap Around Event Log Enable" to "enable" and set to
overwrite old logs.
PRIMERGY BX600 Management Blade Hardware Guide
Enter the e-mail address of the receiver.
Enter the e-mail address of the sender.
Enter the IP address or host name of the host used to access the SMTP service.
The subject of the e-mail. The subject is fixed as PRIMMAIL.
Enter the name of the administrator. An input name is sent as the content of the
mail.
Enter contact phone number of the administrator. An input telephone number is
sent as the content of the mail.
Description
33

Advertisement

Table of Contents
loading