Chapter 5 CLI
❑: Parameter
Parameter
1. System Temperature Critical
Reaction
System Temperature Sensor
Designation
System Temperature Sensor
Status
System Temperature Upper
Warning Level
System Temperature Upper
Critical Level
System Temperature Current
Value
92
Setting
❑
continue
Sets the action for each temperature sensor.
❑
shutdown-and-
• continue
poweroff
Sets operations to continue even during a temperature
error.
• shutdown-and-poweroff
Performs graceful shutdown of the main power supply
of the chassis when a temperature error occurs.
When using refer to "6.2 Points to Note about Remote
Power OFF and the Shutdown Function" ( p.139).
-
Displays the location of each temperature sensor.
• Housing-Left, Center, Right
The left, center and right of the chassis when looking
from the front.
• Ambient
Inside the front control board
• Switch 1 – 4:
Inside the Switch Blade:
• PSU1 – 4
Inside the PSU
-
Displays the status of each temperature sensor.
-
Displays the temperature warning threshold.
-
Displays the temperature danger threshold.
-
Displays the current temperature value of each
temperature sensor.
Contents