This section explains the notes for your safety and conventions used in this manual. Make
sure to read this section.
Chapter 1
About Management Blades
This chapter explains the system features and the component names of Management Blades.
Chapter 2
Installing and Removing Management Blades
This chapter explains how to install/remove Management Blades to the chassis and default
settings.
Chapter 3
Software
This chapter explains the software that can be used in collaboration with Management
Blades.
Chapter 4
Web UI
This chapter explains the Web UI which enables the management and operation of the blade
server system in the Management Blade.
Chapter 5
CLI
This chapter explains the command line interface (CLI) which enables the management/
operation of the blade server system in the Management Blade.
Chapter 6
Technical Information Knowledgebase
This chapter explains the specifications and operational notes of the Management Blade.
PRIMERGY BX600 Management Blade Hardware Guide
1

Advertisement

Table of Contents
loading

Summary of Contents for PRIMERGY BX600 S3

  • Page 1 PRIMERGY BX600 Management Blade Hardware Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read this section. Chapter 1 About Management Blades This chapter explains the system features and the component names of Management Blades.
  • Page 2: For Your Safety

    Before Reading This Manual For Your Safety This manual contains important information, required to operate this product safely. Thoroughly review the information in this manual before using this product. Especially note the points under "Safety Precautions" provided with the Chassis or Server Blade, and only operate this product with a complete understanding of the material provided. This manual and "Safety Precautions"...
  • Page 3 PRIMERGY BX600 Management Blade Hardware Guide Contents This manual supports operation of the PRIMERGY BX600 S3 Blade Server System Unit and BX620 S4 Server Blade. For information on the chassis and Server Blade not described in this manual, refer to the relevant manuals in the Fujitsu PRIMERGY website (http://primergy.fujitsu.com).
  • Page 4 ■ Entering Commands (Keys) Command entries are displayed in the following way: • In the spaces indicated with the "↑" mark, press the [Space] key once. • When using Windows, commands are not case sensitive. • CD/DVD drive names are shown as [CD/DVD drive]. Enter your drive name according to your environment.
  • Page 5 The server or this server PRIMERGY BX600 (Indicates the whole blade server system) PRIMERGY BX600 Management Blade Management Blade or this product PRIMERGY BX600 S3 Blade Server System Chassis Unit PRIMERGY BX620 S4 Server Blade BX620 S4 Server Blade or Server Blade...
  • Page 6 ■ Management Blade Firmware The Web UI/CLI screen configuration and parameters of the Management Blade differ depending on the firmware version. When referring to manuals, use the manual version that matches the Management Blade firmware version being used. This manual describes the Management Blade firmware version V1.62 or later. Microsoft, Windows and Windows Server are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries.
  • Page 7: Table Of Contents

    PRIMERGY BX600 Management Blade Hardware Guide Contents Chapter 1 About Management Blades 1.1 Features ..........10 1.2 Component Names and Functions .
  • Page 8 5.3 CLI Login ..........67 5.4 CLI Menu .
  • Page 9 Chapter 1 About Management Blades This chapter explains the system features and the component names of Management Blades. 1.1 Features ........1.2 Component Names and Functions .
  • Page 10: Features

    Chapter 1 About Management Blades 1.1 Features The Management Blade performs various types of monitoring and control of the status of the power supply, temperature and system fan within the chassis. It is also equipped with LAN ports, which makes monitoring/control possible even from a remote location.
  • Page 11: Component Names And Functions

    PRIMERGY BX600 Management Blade Hardware Guide 1.2 Component Names and Functions This section explains the names and functions of the various parts of this product. 10BASE-T/100BASE-TX (close up) Serial port (9 pin) Management Blade master LED The RS-232C cross cable (one cable is attached with the...
  • Page 12 Chapter 1 About Management Blades...
  • Page 13: Management Blades

    Chapter 2 Installing and Removing Management Blades This chapter explains how to install/remove Management Blades to the chassis and default settings. 2.1 Before Starting ....... . 2.2 Installing and Removing .
  • Page 14: Before Starting

    Chapter 2 Installing and Removing Management Blades 2.1 Before Starting Perform the following preparations before installing/ removing a Management Blade to the chassis. ■ Preparations Before starting prepare the following. • Management Blade • The server and manual for each optional component •...
  • Page 15: Installing And Removing

    PRIMERGY BX600 Management Blade Hardware Guide 2.2 Installing and Removing For details about installing/removing Management Blades, refer to "BX600 S3 Blade Server System Unit Hardware Guide". For the Management Blades to monitor the chassis constantly, blade system management starts approx. 1 minute after the power cable of the chassis has been plugged in.
  • Page 16: Default Settings

    Chapter 2 Installing and Removing Management Blades 2.3 Default Settings Before using the Management Blade, some default settings must be performed. 2.3.1 Management Software Management Blade supports management tools such as Web UI (web user interface) and CLI (command line interface). Using these management tools, the chassis of the blade server and various blades can be easily managed from the management terminal.
  • Page 17 PRIMERGY BX600 Management Blade Hardware Guide Connect the management terminal and Management Blade using a LAN cable according to the network to be used. 1. Connect the LAN cable to the Management Blade. Attach the connector of the LAN cable to the 10BASE-T/100BASE-TX port of the Management Blade.
  • Page 18 Chapter 2 Installing and Removing Management Blades Perform LAN interface settings by clicking on [System Property] – [LAN Interface] in the setting parameter menu of the displayed Management Blade initial screen in this order. For details about setting methods, refer to "● LAN Interface" ( p.29). ■...
  • Page 19: Management User Settings

    PRIMERGY BX600 Management Blade Hardware Guide 2.3.3 Management User Settings A user name "root" and password "root" that have administrator privileges are set by default to the Management Blade. To ensure the security, make sure to change the password. ■ Changing the password from Web UI Access the Web UI from the management terminal.
  • Page 20: Blade Server Time Management

    Chapter 2 Installing and Removing Management Blades 2.3.4 Blade Server Time Management It is necessary to perform/check Management Blade time and time zone settings during initial setting. Perform checks/settings in Web UI ( "● System Information" (p.45)) or CLI ( "■ Management Agent Information (1_1)"...
  • Page 21: Various Setting Values

    PRIMERGY BX600 Management Blade Hardware Guide 2.3.5 Various Setting Values In order to operate the Management Blade, perform settings in order to they conform with the installation environment on the management tools. Store the various setting values set in the Management Blade in the hard copy of screens, take note, or record in the Configuration Sheets.
  • Page 22 Chapter 2 Installing and Removing Management Blades...
  • Page 23: Chapter 3 Software

    Chapter 3 Software This chapter explains the software that can be used in collaboration with Management Blades. 3.1 Software ........
  • Page 24: Software

    • RemoteControlService V3.06 or later CLI operations can be performed via Telnet. ServerView management console and RemoteControlService are stored in the PRIMERGY Startup Disc. For details about how to install ServerView and RemoteControlService, refer to the "Server Blade User's Guide"...
  • Page 25: Chapter 4 Web Ui

    Chapter 4 Web UI This chapter explains the Web UI which enables the management and operation of the blade server system in the Management Blade. 4.1 Accessing Web Interface ......4.2 Web UI Menu .
  • Page 26: Accessing Web Interface

    Chapter 4 Web UI 4.1 Accessing Web Interface Management Blade supports Web interface (Web UI) and can be accessed from the following Web browsers. • Internet Explorer (Version 5.0, 5.5, 6.0 or later) • Netscape (Version 4.75, 4.78, 6.x or later *: When using the SSL function, Version 7.0 or later is required.
  • Page 27: Start Screen

    PRIMERGY BX600 Management Blade Hardware Guide Web UI Menu 4.2.1 Start Screen Access the start address and enter the user name and password. When they are recognized, the Management Blade initial screen will be displayed as the start screen. Web UI settings start from this screen.
  • Page 28: Settings Menu

    Chapter 4 Web UI 4.2.2 Settings Menu The system configuration, properties and blades installed in the blade server system are displayed in the settings menu on the left side of the screen. This page is divided into 4 groups, "System Property", "Management Blade", "Switch Blade"...
  • Page 29 PRIMERGY BX600 Management Blade Hardware Guide ● LAN Interface Performs settings for network configuration. "● LAN Interface" (p.39) • Internet Protocol Sets the IP address etc. • Domain Name Server Sets DNS. • HTTP Sets the port number etc. of the HTTP.
  • Page 30 Chapter 4 Web UI ● User Accounts Adds new users and changes the password. "● User Accounts" (p.46) ● Deployment Table Displays and sets the Parameters of various Server Blades that can be used with Deployment software. "● Deployment Table" (p.47) ●...
  • Page 31: System Settings

    PRIMERGY BX600 Management Blade Hardware Guide 4.2.3 System Settings Page The system settings page displayed in the right of the screen shows the various settings and information of the item selected in the settings menu. In the system settings page all the page header and footer areas are configured using the same method.
  • Page 32: System Property Group

    Chapter 4 Web UI 4.2.4 System Property Group This group is used for system configuration. ● System Event Log The Management Blade and Server Blade event logs are displayed and alarm handler settings are performed on the System Event Log page. Management Blade logs include event logs related to the chassis.
  • Page 33 PRIMERGY BX600 Management Blade Hardware Guide - Critical Event Critical events are displayed. If the problem is not solved, it may cause an error in the operations of the system. All logs can be deleted by clicking [Clear All Entries].
  • Page 34 On the Power Supply page, information such as the temperature of the PSU, the internal fans and running time is displayed and ON/OFF is set. The Power Supply page is explained below. PSU and dummy PSU are non-durable components (→ "BX600 S3 Blade Server System Unit Hardware Guide"). Change settings after replacement.
  • Page 35 PRIMERGY BX600 Management Blade Hardware Guide Display/Parameter Description System Power Supply This item only appears when four power supply units are installed. Redundancy Mode Sets the system power supply redundancy mode. • 3+1: If one of four PSUs is failed, the system can be operated with the other three.
  • Page 36 Chapter 4 Web UI • Chassis Chassis and system fan unit information is displayed in the Chassis page. Internal temperature displays of the chassis and actions for temperature errors can also be set. The Chassis page is explained below. Display/Parameter Description Chassis Product Displays the product version of the chassis.
  • Page 37 PRIMERGY BX600 Management Blade Hardware Guide • Fans The status of fans is displayed and actions for fan failure are set in the Fans page. The Fans page is explained below. Display/Parameter Description Displays the numbers of each fan. Status Displays the status of each fan.
  • Page 38 Chapter 4 Web UI Display/Parameter Description Contact Check Box When the life time of the system fan unit is over, check the check box after contacting a service representative. When [Reset] is clicked it is unchecked. Not used for this product. Apply Applies the input information.
  • Page 39 PRIMERGY BX600 Management Blade Hardware Guide ● LAN Interface Management Blade provides network service functions such as Web server, Telnet, SMTP, DNS, NTP, SSL etc. Network configuration settings are performed on this page. Click [Apply LAN Configuration] and settings are reflected. It is necessary to reboot Management Blade for some of the settings.
  • Page 40 Chapter 4 Web UI • Domain Name Server Domain Name Server (DNS) is set on the Domain Name Server page. Display/Parameter Description DNS Server 1 Sets the IP address of the primary DNS server. DNS Server 2 Sets the IP address of the secondary DNS server. •...
  • Page 41 PRIMERGY BX600 Management Blade Hardware Guide Display/Parameter Description Sync Mode Specifies the time synchronization mode. • Sync Afterward The time of the Management Blade is synchronized to the time of the NTP server only when the time of the NTP server is fast. When using this for operations that demand time to be taken into careful consideration such as databases, select this mode.
  • Page 42 Chapter 4 Web UI ● SNMP Interface SNMP community names and trap destinations are set on the SNMP Interface page. • SNMP Communities Adding and deleting of SNMP community names is performed on the SNMP Communities page. • Community If you input the new community name and click [New Community], the new community name is added.
  • Page 43 PRIMERGY BX600 Management Blade Hardware Guide ● Console Redirection Telnet/HTTP/SNMP filtering and KVM switching are set on the Console Redirection page. • Keyboard/Mouse/Video Switch to Local On the Keyboard/Mouse/Video Switch to Local page, switches which Server Blade of which slot is to be used for the keyboard/display/mouse connected to the chassis.
  • Page 44 Chapter 4 Web UI ● Fiber Channel The status of the FC Pass-Thru Blades is displayed on the Fiber Channel page. • FC Pass Through Card-1 / FC Pass Through Card-2 • FC Pass Through Status Displays the status of the FC Pass-Thru Blade. •...
  • Page 45 PRIMERGY BX600 Management Blade Hardware Guide ● System Information SNMP agent information and Management Blade time/time zone are set on the System Information page. • Agent Information Sets SNMP agent information. Display/Parameter Description Name Sets the system name of the Management Blade to identify the device in SNMP.
  • Page 46 Chapter 4 Web UI ● User Accounts New user name creation, password and privilege settings and deletion of existing user accounts can be performed in the User Account page. Without administrators privileges, user related operations cannot be performed. Click an existing user name or [Add New User Account] and the Accounts page in which user account changes can be made or new user accounts created is displayed.
  • Page 47 PRIMERGY BX600 Management Blade Hardware Guide ● Deployment Table Displays and sets the following Deployment Parameters for each installed blade. Deployment Parameters can be used in various types of Deployment software and ServerView. By selecting an installed Server Blade from the pull down menu the Deployment Parameters of various Server Blades are set.
  • Page 48: Management Blade Group

    Chapter 4 Web UI 4.2.5 Management Blade Group Displays all the installed Management Blades. Click the link and the following information will be displayed for Management Blade. Display/Parameter Description Blade Information Blade information Play Role Displays the operation mode of the Management Blade. •...
  • Page 49: Lan Switch Blade Group

    PRIMERGY BX600 Management Blade Hardware Guide 4.2.6 Lan Switch Blade Group Displays all the installed Switch Blades. Click the link and the following information will be displayed for Switch Blades. Click [Reload] to update the displayed Switch Blade information. However, the information is not updated when the Switch Blade is not activated or straight after a replacement.
  • Page 50: Phy Module Group

    Chapter 4 Web UI Display/Parameter Description Switch Blade Period This section is displayed only for Cisco Catalyst Blade Switch 3040. Determines whether or not to enable the regular settings confirmation polling to Cisco Catalyst Blade Switch 3040 by the Management Blade. Set Password for This section is displayed only for Cisco Catalyst Blade Switch 3040.
  • Page 51: Fc Switch Blade Group

    PRIMERGY BX600 Management Blade Hardware Guide 4.2.8 FC Switch Blade Group All the installed FC Switch Blades are displayed. Click the link and the following information will be displayed for each Fibre Channel Switch. Display/Parameter Description Located LED This acts as the FC Switch Blade identification function to set the fibre channel maintenance lamp display.
  • Page 52: Adv. Kvm Blade Group (When Pg-Kvb102 Is Installed)

    Chapter 4 Web UI Display/Parameter Description FC Switch Blade Period Polling Sets whether or not to enable checking of the FC Switch Blade settings by the Management Blade on a regular basis. Check the [enable] box and click [Apply] to enable checking the settings on a regular basis.
  • Page 53: Dkvm Blade Group (When Pg-Kvb103 Is Installed)

    PRIMERGY BX600 Management Blade Hardware Guide Display/Parameter Description KVM Redirection One of the following is displayed. [Launch]: When clicked, starts graphical console redirection to the Server Blade. [Adv. KVM had been launched by user <Date Time>]: Displays the graphical console redirection has opened in the Date-Time.
  • Page 54 Select the Server Blade from the pull-down menu and click [Launch] to start Video Viewer and operate the Server Blade screen. For details about using the Video Viewer for console redirection, refer to the "PRIMERGY BX600 S3 Blade Server System Unit Hardware Guide".
  • Page 55: Server Blade Group

    PRIMERGY BX600 Management Blade Hardware Guide 4.2.11 Server Blade Group All the Server Blades/Storage Blades installed in the chassis are shown in Server Blade group. The power supply status and the keyboard/display/mouse (KVM) select location are both shown as an icon at the same time.
  • Page 56 Even when ServerView is installed to the Server Blade, When starting the system while the PRIMERGY Startup Disc or floppy disks for activating hardware configuration tools is inside, be sure to disable the OS Boot Monitoring function (default settings are disable).
  • Page 57 PRIMERGY BX600 Management Blade Hardware Guide • CMOS Restore Restores the CMOS settings of BIOS. It is necessary to restart Server Blade to enable the BIOS information. Restart as necessary. This function cannot be used when the Server Blade that backed up the CMOS settings and the restore destination Server Blade differs or when the BIOS version differs.
  • Page 58 Chapter 4 Web UI - Hard Power off The Server Blade is forcibly turned off. When ordering power on after ordering Server Blade power off, check that the power has been turned off first. • Power On/Off Sets the Server Blade scheduled operations. Orders for scheduled operations are given from the Management Blade.
  • Page 59 PRIMERGY BX600 Management Blade Hardware Guide • Boot CPU Operating Displays the operation mode of the CPU installed to the Server Blades. - Performance The CPU installed to the Server Blade in operating in Performance mode. - not-ready The CPU is not operating.
  • Page 60 Chapter 4 Web UI • Processors Displays various CPU information. Display/Parameter Description Displays the CPU number. Status Displays the status of the CPU. Type Displays the CPU type. Frequency Displays the clock frequency of the CPU. External Clock Displays the clock frequency of the CPU bus. CPU ID Displays the CPU stepping.
  • Page 61 PRIMERGY BX600 Management Blade Hardware Guide • Temperature, server blade n Displays the settings of the various temperature and temperature thresholds on the Server Blade board. Display/Parameter Description Displays the number of each temperature sensor. Status Displays the status of each temperature sensor.
  • Page 62 Chapter 4 Web UI...
  • Page 63: Chapter 5 Cli

    Chapter 5 This chapter explains the command line interface (CLI) which enables the management/ operation of the blade server system in the Management Blade. 5.1 CLI Connection Methods ......5.2 Basic Operations of Each Screen .
  • Page 64: Cli Connection Methods

    Chapter 5 CLI 5.1 CLI Connection Methods This chapter explains CLI connection methods using Telnet via LAN or a serial interface. When using CLI via LAN using Telnet it is recommended to use the following software. • RemoteControlService V3.06 or later 5.1.1 Using Serial Interface Connect Management Blade to the management terminal using an RS-232C cross cable.
  • Page 65: Using Telnet Via Lan Interface

    PRIMERGY BX600 Management Blade Hardware Guide 5.1.2 Using Telnet via LAN Interface Connect Management Blade to the management terminal using a LAN cable. "■ LAN Interface Settings" (p.16) Start the Telnet client software in the management terminal and specify the IP address and port number of the Management Blade to connect the Management Blade to the management terminal.
  • Page 66: Basic Operations Of Each Screen

    Chapter 5 CLI 5.2 Basic Operations of Each Screen In the CLI page, if you enter the numbers shown on the screen after "Enter Selection:" and press [Enter], information can be set and displayed and pages can be changed. • When entering setting values, enter the number or letter strings in accordance with the directions displayed on the screen after the symbol [- - >>].
  • Page 67: Cli Login

    PRIMERGY BX600 Management Blade Hardware Guide 5.3 CLI Login If terminal software is started on the management terminal during Management Blade operations, the following login screen will appear. If the Management Blade is not operating, connect the power supply cable. A self-diagnostic test message appears and then the login screen appears.
  • Page 68 Chapter 5 CLI If you connect a serial interface to a Management Blade operating in slave mode, [Welcome to Management Blade] window is displayed and the following slave mode login screens appear. Because settings cannot be performed from a Management Blade in slave mode, display the master mode login screen using one of the following methods.
  • Page 69: Cli Menu

    PRIMERGY BX600 Management Blade Hardware Guide 5.4 CLI Menu This section explains the various types of CLI menus and methods of operation. Because the majority of the Parameters are the same as those of the Web UI, for details about Parameters refer also to "Chapter 4 Web UI" ( pg.25).
  • Page 70: Management Agent

    Chapter 5 CLI 5.4.2 Management Agent Displays and sets various information of the blade server system. +------------------------------------------+ Management Agent page_1 +------------------------------------------+ Management Agent Information Management Blade System Information Server Blade Switch Blade Username And Password Blue Screen Event Log Set System Default (10) Server Blade CMOS Backup/Restore (11) Switch Blade Configuration Backup/Restore (12) Deployment Parameter...
  • Page 71 PRIMERGY BX600 Management Blade Hardware Guide Menu Description 15. Fiber Channel Displays the status of the FC Pass-Thru Blade. "■ Fiber Channel (1_15)" (p.125) 16. PHY Module Displays the status of the GbE Pass-Thru Blade. "■ PHY Module (1_16)" (p.127) 17.
  • Page 72 Chapter 5 CLI Parameter Setting Contents 7. Set Management Agent Date Sets the time of the Management Blade. <Enter in the Time format of month/day/year hour:minute:second>. Time is set in 24 hour format. ❑ 8. Set Management Agent 30– 65535 Sets the timeout value during console login.
  • Page 73 PRIMERGY BX600 Management Blade Hardware Guide ● 12. Agent HTTP (1_1_12) Sets the HTTP agents in the Management Blade. +------------------------------------------+ Agent HTTP page_1_1_12 +------------------------------------------+ (1) Set HTTP Enable : enable (2) Set HTTP Port : 80 (3) Set HTTP SSL Enable : disable...
  • Page 74 Chapter 5 CLI ● 13. Agent SNMP (1_1_13) Sets the SNMP agents in the Management Blade. +------------------------------------------+ Agent SNMP page_1_1_13 +------------------------------------------+ (1) Set Agent SNMP Enable : enable (2) Set Agent SNMP Security Enable : disable (3) Agent SNMP Trap Table (4) Agent SNMP Community String Table (5) SNMP IP Filter Table Enter selection or type (0) to quit:...
  • Page 75 PRIMERGY BX600 Management Blade Hardware Guide • 3. Agent SNMP Trap Table (1_1_13_3) Sets and displays a SNMP trap destination table. +------------------------------------------+ Agent SNMP Trap Table page_1_1_13_3 +------------------------------------------+ (1) Agent SNMP Trap 1 : 0.0.0.0 (2) Agent SNMP Trap 2 : 0.0.0.0 (3) Agent SNMP Trap 3 : 0.0.0.0...
  • Page 76 Chapter 5 CLI • 5. SNMP IP Filter Table (1_1_13_5) Performs IP settings that permit SNMP connection. A maximum of 10 IP that permit SNMP can be registered. 255.255.255.255, that was set at the time of purchase, does not perform IP filtering. When performing IP filtering, delete it as necessary.
  • Page 77 PRIMERGY BX600 Management Blade Hardware Guide ❑ : Parameter Parameter Setting Contents ❑ 1. Set Telnet Enable enable Sets Telnet service enable/disable. Settings become valid ❑ disable after restarting the Management Blade. 2. Set Telnet Port Sets the port number of telnet.
  • Page 78 Chapter 5 CLI ● 15. Agent DNS (1_1_15) Sets DNS of the Management Blade. +------------------------------------------+ Agent Network DNS page_1_1_15 +------------------------------------------+ (1) Set DNS IP Address_1 : 0.0.0.0 (2) Set DNS IP Address_2 : 0.0.0.0 Enter selection or type (0) to quit: Parameter Contents 1.
  • Page 79 PRIMERGY BX600 Management Blade Hardware Guide Parameter Setting Contents 2. NTP Server IP Enter the IP address of the NTP server. "• 2. NTP Server IP (1_1_17_2)" (p.79) The Lastest Sync Date/Time This displays the latest time at which Management Blades and NTP server time synchronization was performed.
  • Page 80 Chapter 5 CLI ● 18. Agent NIC Duplex Mode (1_1_18) Sets the NIC transmission rate of the Management Blade. +------------------------------------------+ Agent NIC Duplex Mode page_1_1_18 +------------------------------------------+ (-) Execution Mode : Auto-Negotiation (3) NIC Mode : Auto-Negotiation Enter selection or type (0) to quit: ❑: Parameter Parameter Setting...
  • Page 81 PRIMERGY BX600 Management Blade Hardware Guide Parameter Contents Management Blade_1 – Selects the Management Blade number to display the various information of the Management Blade_2 Management Blade. "● Management Blade (1_2_1)" (p.81) ● Management Blade (1_2_1) Displays various information of the selected Management Blade.
  • Page 82 Chapter 5 CLI ■ System Information (1_3) Checks / Sets the status of the blade server system and configuration information of the power supply unit, system fan unit, temperature, etc. +------------------------------------------+ System Information page_1_3 +------------------------------------------+ (1) System Control Information (2) System Power Supply (3) System Fan (4) System Temperature (5) System Chassis Table...
  • Page 83 PRIMERGY BX600 Management Blade Hardware Guide Parameter Setting Contents 10. Turn on/off all server blades Sets the power supply of all the installed Server Blades. "● 10. Turn on/off all server blades (1_3_10)" (p.95) ● 1. System Control Information (1_3_1) Displays system information.
  • Page 84 Chapter 5 CLI ● 2. System Power Supply (1_3_2) Displays the state of the power supply. +------------------------------------------+ System Power Supply page_1_3_2 +------------------------------------------+ (1) System Power Supply Control : Hard Power off (-) System Power Supply Status : not-ready (-) System Power Supply Redundancy : yes (4) System Power Supply Unit Table (5) System Power supply Redundancy Mode: 3+1...
  • Page 85 PRIMERGY BX600 Management Blade Hardware Guide Parameter Setting Contents ❑ 5. System Power supply This item only appears when four power supply units are ❑ Redundancy Mode installed. Sets the system power supply redundancy mode. • 3+1: If one of four PSUs is failed, the system can be operated with the other three.
  • Page 86 Displays the Over Voltage Protection (OVP) status. System Power Supply OCP Displays the Over Current Protection (OCP) status. PSU replacement PSU and dummy PSU are non-durable components (→ "BX600 S3 Blade Server System Unit Hardware Guide"). Change settings after replacement.
  • Page 87 System Fans Overall Status Displays the overall status of the system fans. Important: System fan units are non-durable components (→ "BX600 S3 Blade Server System Unit Hardware Guide"). Change settings after replacement. ❑ 6. All Rear Fans Unavailable...
  • Page 88 Chapter 5 CLI • 1. System Fans Table (1_3_3_1) Displays a table showing the fans installed in the chassis and PSU. +------------------------------------------+ System Fan page_1_3_3_1 +------------------------------------------+ (1) Rear1-Fan-1 : ** (2) Rear1-Fan-2 : ** (3) Rear2-Fan-1 : ** (4) Rear2-Fan-2 : ** (5) PowerUnit1-Fan-1 : ** (6) PowerUnit1-Fan-2 : **...
  • Page 89 PRIMERGY BX600 Management Blade Hardware Guide ❑: Parameter Parameter Setting Contents ❑ 1. System Fan Fail Reaction continue Sets the action for each fan. ❑ shutdown-and- • continue poweroff Sets operations to continue even during a fan failure. • shutdown-and-poweroff Performs graceful shutdown of the main power supply of the chassis when a fan error occurs.
  • Page 90 Chapter 5 CLI • 2. System Fans Live Time Table (1_3_3_2_1) The information related to the running time of the selected system fan unit can be set and displayed. +------------------------------------------+ System Fan page_1_3_3_2_1 +------------------------------------------+ (-) Fan Running Time (2) Fan Live Time Reset : reset (3) Fan Live Time : 26000...
  • Page 91 PRIMERGY BX600 Management Blade Hardware Guide Parameter Contents 1. System Temperature Sensor Displays system temperature status. Displays a list of temperature sensors and Table their status. "• 1. System Temperature Sensor Table (1_3_4_1)" (p.91) System Temperature Overall Displays the overall status of the temperature sensors of the system.
  • Page 92 Chapter 5 CLI ❑: Parameter Parameter Setting Contents ❑ 1. System Temperature Critical continue Sets the action for each temperature sensor. ❑ Reaction shutdown-and- • continue poweroff Sets operations to continue even during a temperature error. • shutdown-and-poweroff Performs graceful shutdown of the main power supply of the chassis when a temperature error occurs.
  • Page 93 PRIMERGY BX600 Management Blade Hardware Guide ● 5. System Chassis Table (1_3_5) Displays the status of the chassis system fan and serial number. +------------------------------------------+ System Chassis page_1_3_5 +------------------------------------------+ (1) System Chassis Intrusion Table (-) System Chassis Serial Number : **...
  • Page 94 Chapter 5 CLI ● 9. NIC Status Detection (1_3_9) Sets NIC status detection. +--------------------------------------------+ NIC Status Detection page_1_3_9 +--------------------------------------------+ (1) NIC Status Detection : disable (2) NIC Detection Timeout : 120 Enter selection or type (0) to quit: ❑: Parameter Parameter Setting Contents...
  • Page 95 PRIMERGY BX600 Management Blade Hardware Guide Parameter Setting Contents ❑ 2. NIC Detection Timeout 0 – 300 Sets the time (seconds) for NIC status detection. If communication does not take place in the setting time here, a NIC status self diagnostic test is performed.
  • Page 96 Chapter 5 CLI ■ Server Blade (1_4) Displays and sets the various information of Server Blades. +------------------------------------------+ Server Blade page_1_4 +------------------------------------------+ (1) Server Blade_1: ok (2) Server Blade_2: ok (3) Server Blade_3: ok (4) Server Blade_4: ok (5) Server Blade_5: ok (6) Server Blade_6: ok (7) Server Blade_7: ok (8) Server Blade_8: ok...
  • Page 97 PRIMERGY BX600 Management Blade Hardware Guide Parameter Contents 3. Server Blade CPU Displays the information of the CPU installed to the Server Blades. "● 3. Server Blade CPU (1_4_1_3)" (p.100) 4. Server Blade Memory Displays the information of the memory installed to the Server Blades.
  • Page 98 Chapter 5 CLI ❑: Parameter Parameter Setting Contents ❑ 1. Server power Power On Sets Server Blade power supply. ❑ graceful When using, refer to "6.2 Points to Note about Remote shutdown and off Power OFF and the Shutdown Function" ( p.139). ❑...
  • Page 99 PRIMERGY BX600 Management Blade Hardware Guide Parameter Setting Contents ❑ 4. Server LED Control blinking Sets the display of the Server Blade power supply LED ❑ as the Server Blade identification function. Used to identify the multiple Server Blade installed in the chassis.
  • Page 100 Chapter 5 CLI Parameter Contents Server Blade KME Version Displays the KME (keyboard mouse emulator) version. Number of CPU Socket Displays the number of CPU sockets. Number of Memory Socket Displays the number of the memory slots installed. Server Blade OS Type Displays the OS type if ServerView agent is installed to the OS.
  • Page 101 PRIMERGY BX600 Management Blade Hardware Guide • Server Blade CPU Information (1_4_1_3_1) Displays the detailed information of the selected CPU. +------------------------------------------+ Server Blade CPU Information page_1_4_1_3_1 +------------------------------------------+ (-) CPU Type : ** (-) CPU Frequency : ** (-) CPU ID...
  • Page 102 Chapter 5 CLI ● 4. Server Blade Memory (1_4_1_4) Displays the information of the memory installed to the Server Blades. +------------------------------------------+ Server Blade Memory page_1_4_1_4 +------------------------------------------+ (1) Server Blade Memory Information Table (2) Server Blade Memory Modules Table Enter selection or type (0) to quit: Parameter Contents 1.
  • Page 103 PRIMERGY BX600 Management Blade Hardware Guide • 2. Server Blade Memory Modules Table (1_4_1_4_2) Displays the status of the installed memory modules. The figure uses BX620 S4 Server Blade as an example. +------------------------------------------+ Server Blade Memory Module Table page_1_4_1_4_2 +------------------------------------------+...
  • Page 104 Chapter 5 CLI Parameter Contents Memory Module Socket Displays the socket location to which memory module is installed. Designation Memory Module Speed Displays the operating frequency of the memory bus. ● 5. Server Blade Voltage Table (1_4_1_5) Displays the information about the voltage of the Server Blades. The figure uses BX620 S4 Server Blade as an example.
  • Page 105 PRIMERGY BX600 Management Blade Hardware Guide Parameter Contents Server Voltage Designation Displays the location of each voltage sensor. Server Voltage Status Displays the status of each voltage sensor. Server Voltage Minimum Value Displays the minimum danger threshold for voltage. Server Voltage Maximum Value Displays the maximum danger threshold for voltage.
  • Page 106 Chapter 5 CLI • Server Temperature Sensor Information Table (1_4_1_6_1) Displays the detailed information of the selected measured temperature. +----------------------------------------------+ Server Temperature Sensor Information Table page_1_4_1_6_1 +----------------------------------------------+ (-) Server Temperature Sensor Designation : SYSTEM TEMP1 (-) Server Temperature Sensor Status : ** (-) Server Temperature Upper Warning Level : **...
  • Page 107 PRIMERGY BX600 Management Blade Hardware Guide ● 7. Server Blade NIC Information (1_4_1_7) Displays the information about the onboard NIC of the Server Blades. +------------------------------------------+ Server NIC Information page_1_4_1_7 +------------------------------------------+ (1) Server Blade NIC IP Table (2) Server Blade MAC Address Table...
  • Page 108 Chapter 5 CLI • 2. Server Blade MAC Address Table (1_4_1_7_2) Displays the MAC address for Server Blade. The figure uses BX620 S4 Server Blade as an example. +------------------------------------------+ Server Blade MAC Address page_1_4_1_7_2 +------------------------------------------+ (-) NIC1 : nn:nn:nn:nn:nn:nn (-) NIC2 : nn:nn:nn:nn:nn:nn (-) NIC3 : nn:nn:nn:nn:nn:nn (-) NIC4 : nn:nn:nn:nn:nn:nn (-) NIC5 : nn:nn:nn:nn:nn:nn...
  • Page 109 PRIMERGY BX600 Management Blade Hardware Guide • 1. Server Blade Software Watchdog (1_4_1_8_1) Displays the OS hang monitor function of the Server Blade. Settings are performed on ServerView. +------------------------------------------+ Software Watchdog Information page_1_4_1_8_1 +------------------------------------------+ (-) Software Watchdog Time : 0.00...
  • Page 110 "disable". If the setting is "enable", there is a fear that this server may automatically turn off or restart improperly. Even when ServerView is installed to the Server Blade, if starting the system while the PRIMERGY Startup Disc or floppy disks for activating hardware configuration tools is inside, be sure to disable the "OS Boot Monitoring"...
  • Page 111 PRIMERGY BX600 Management Blade Hardware Guide ■ Switch Blade (1_5) Displays various information of the Switch Blade. +------------------------------------------+ Switch Blade page_1_5 +------------------------------------------+ (1) Switch Blade_1: ok (2) Switch Blade_2: ok (3) Switch Blade_3: ok (4) Switch Blade_4: ok Enter selection or type (0) to quit:...
  • Page 112 Chapter 5 CLI ❑: Parameter Parameter Setting Contents Administrative URL Displays the URL of the Switch Blade Web interface. Switch Blade Status Displays the overall status of Switch Blade. Switch Blade Manufacture Displays the manufacturer. Switch Blade Manufacture Date Displays the manufacture date. Switch Blade Serial Number Displays the system serial number.
  • Page 113 PRIMERGY BX600 Management Blade Hardware Guide • 19. Reboot Switch Blade (1_5_1_19) Reboots the Switch Blade. +------------------------------------------+ page_1_5_1_19 +------------------------------------------+ Reboot Switch Blade (1) reboot now! (0) quit Enter selection : Parameter Contents 1. reboot now! If selected reboots the Switch Blade.
  • Page 114 Chapter 5 CLI ● Edit Username And Password (1_6_1) Sets password etc. for the selected user. +------------------------------------------+ Edit Username And Password page_1_6_1 +------------------------------------------+ (1) Change Username : root (2) Change Password : **************** (3) User Permission : 255 Enter selection or type (0) to quit: ❑: Parameter Parameter Setting...
  • Page 115 PRIMERGY BX600 Management Blade Hardware Guide ■ Event Log (1_8) Checks event logs related to Management Blades and Server Blades. +------------------------------------------+ Event Log page_1_8 +------------------------------------------+ (1) Management Blade Event Log (2) Server Blade Event Log Table (3) Server Blade Power On/Off Event Log Enable : disable...
  • Page 116: Server Blade Event Log Table

    Chapter 5 CLI ● 2. Server Blade Event Log Table Checks the logs of the Server Blades installed in the chassis. After selection, log filtering and deletion is performed in the following screen. +------------------------------------------+ Manage Blade Event Log Level page_1_8_1 +------------------------------------------+ (1) All Event (2) Informational Event...
  • Page 117 PRIMERGY BX600 Management Blade Hardware Guide When "Management Blade Wrap Around Event Log Enable" is set to "disable" in Management Blade, if the maximum number of event logs is reached, no more event logs can be recorded. Periodically check "Event Log" and save or delete logs as necessary. Save by copying the screen text.
  • Page 118 Chapter 5 CLI ■ Server CMOS Backup/Restore (1_10) Performs the backup/restore of CMOS information specified by the BIOS setup utility of the Server Blade. After turning on the Server Blade operations cannot be performed until POST ends. Server Blades that are available for operation are displayed as [Ready].
  • Page 119 PRIMERGY BX600 Management Blade Hardware Guide ● Server CMOS Configure (1_10_1) Sets the CMOS file of the selected Server Blade. +------------------------------------------+ Server CMOS Configure page_1_10_1 +------------------------------------------+ CMOS Control CMOS Configure Restore Target : ** Server CMOS ID With BIOS Version : nnnn...
  • Page 120 Chapter 5 CLI Parameter Contents 1. backup Backs up the BIOS information of the selected Server Blade. 2. smart-restore Perform smart restore of the data backed up in this slot to the Server Blade installed in the slot selected in "CMOS Configure Restore Target". BIOS information can only be restored if the MAC address and slot number of the Server Blade that backed up BIOS information and of the restore target is the same.
  • Page 121 PRIMERGY BX600 Management Blade Hardware Guide ■ Switch Blade Configuration Backup/Restore (1_11) Backs up and restores the various settings to Switch Blade. +--------------------------------------------+ Switch Blade [Last Action] [Last Done Backup Date] page_1_11 +--------------------------------------------+ Blade_1 : [ none] [None Configuration Backup]...
  • Page 122 Chapter 5 CLI ❑: Parameter Parameter Setting Contents 1. Backup/restore Control Controls backup and restore. "• Backup/restore Control (1_11_1_1)" (p.122) 2. View Backup Configuration Displays backed up setting information. ❑ 3. Auto Restore Enable enable Sets whether the backed up setting information will be ❑...
  • Page 123 PRIMERGY BX600 Management Blade Hardware Guide ■ Deployment Parameter (1_12) Displays and sets the Parameters for Deployment for the each installed blade. +------------------------------------------+ Deployment Configuration page_1_12 +------------------------------------------+ Server Blade_1 Server Blade_2 Server Blade_3 Server Blade_4 Server Blade_5 Server Blade_6 Server Blade_7...
  • Page 124 Chapter 5 CLI ● Deployment Configuration (1_12_1) Displays and sets the Parameters for Deployment for the selected blade. +------------------------------------------+ Deployment Configuration page_1_12_1 +------------------------------------------+ Chassis ID : nn Slot : nn MAC Address_1 : nn:nn:nn:nn:nn:nn MAC Address_2 : nn:nn:nn:nn:nn:nn IP Address_1 : n.n.n.n IP Address_2 : n.n.n.n...
  • Page 125 PRIMERGY BX600 Management Blade Hardware Guide ■ Fiber Channel (1_15) Displays various information of the FC Pass-Thru Blade. +------------------------------------------+ Fiber_Channel Table page_1_15 +------------------------------------------+ (1) FC Pass Through_1 : ok (2) FC Pass Through_2 : ok Enter selection or type (0) to quit:...
  • Page 126 Chapter 5 CLI ● FC Pass Through Information (1_15_1) Displays the information of the selected FC Pass-Thru Blade. +------------------------------------------+ FC Pass Through Information page_1_15_1 +------------------------------------------+ (-) FC Pass Through Status : ok (-) FC Pass Through Manufacture : ** (-) FC Pass Through Manufacture Date : DD/MM/YYY nn:nn:nn (-) FC Pass Through Serial Number : **...
  • Page 127 PRIMERGY BX600 Management Blade Hardware Guide ■ PHY Module (1_16) Displays various information of the GbE Pass-Thru Blade. +------------------------------------------+ PHY Module page_1_16 +------------------------------------------+ (1) PHY MODULE_1 (2) PHY MODULE_2 (3) PHY MODULE_3 (4) PHY MODULE_4 Enter selection or type (0) to quit:...
  • Page 128 Chapter 5 CLI ● PHY Module Information (1_16_1) Displays the various information of the selected GbE Pass-Thru Blade. +------------------------------------------+ LAN Pass Through Information page_1_16_1 +------------------------------------------+ (-) LAN Pass Through Manufacture : *** (-) LAN Pass Through Manufacture Date : *** (-) LAN Pass Through Serial Number : *** (-) LAN Pass Through Product Name...
  • Page 129 PRIMERGY BX600 Management Blade Hardware Guide ■ FC Switch (1_17) Displays various information of the FC Switch Blade. +----------------------------------------+ FC SWITCH Table page_1_17 +----------------------------------------+ (1) FC SWITCH MODULE_1 (2) FC SWITCH MODULE_2 Enter selection or type (0) to quit: 1...
  • Page 130 Chapter 5 CLI Parameter Contents FC SWITCH Hardware Version Displays the hardware version. FC SWITCH IP Address Displays the IP Address of the management LAN interface set in the FC Switch Blade. FC SWITCH Subnet Mask Displays the subnet mask of the management LAN interface set in the FC Switch Blade.
  • Page 131 PRIMERGY BX600 Management Blade Hardware Guide ● Storage Server Blade Information (1_19_2) Displays various information about the selected Storage Blade. +--------------------------------------------+ Storage Server Blade Information page_1_19_2 +--------------------------------------------+ (-) Storage Blade Manufacture : FSC (-) Storage Blade Manufacture Date : 05/20/2003 11:50:00...
  • Page 132: Console Redirection

    Chapter 5 CLI 5.4.3 Console Redirection Server Blade and Switch Blade console redirection can be performed from the Management Blade. Server Blade performs POST screen display and BIOS setup utility operations. Switch Blade performs console menu display and operations. Console redirection can only be used for one of multiple installed Server Blades or Switch Blades at a time.
  • Page 133 PRIMERGY BX600 Management Blade Hardware Guide ■ 1. Console Redirect Server Blade (3_1) Performs Server Blade console redirection. +------------------------------------------+ Console Redirect Server Blade page_3_1 +------------------------------------------+ (1) Console Redirect Server Blade_1 Enter selection or type (0) to quit: A list of the installed Server Blades is displayed.
  • Page 134 Chapter 5 CLI Escape sequence [Esc] → [@] [F12] [Esc] → [h] [HOME] [Esc] → [k] [End] [Esc] → [+] [Ins] [Esc] → [-] [Del] [Esc] → [?] [Page Up] [Esc] → [/] [Page Down] [Esc] → [w] [↑] [Esc] → [x] [↓] [Esc] →...
  • Page 135: Logout

    PRIMERGY BX600 Management Blade Hardware Guide 5.4.4 Logout Logs out and returns to the login screen. 5.4.5 Reboot Reboots the Management Blade. +------------------------------------------+ Reboot Selection: [1] Yes [0] No page_6 +------------------------------------------+ (1) Yes,Reboot Now! Enter selection or type (0) to quit: Select (1) and the following screen is displayed and then Management Blade is rebooted.
  • Page 136: System Information Dump

    Chapter 5 CLI 5.4.6 System Information Dump Displays the various information of blades installed to the chassis. This menu is used when dumping information via the CLI. Check in the menu of each unit. +------------------------------------------+ System Information Dump page_7 +------------------------------------------+ (1) System Configuration/Status (2) SEL for Management Blade (3) Server Blade Configuration/Status...
  • Page 137: Technical Information

    Chapter 6 Technical Information Knowledgebase This chapter explains the specifications and operational notes of the Management Blade. 6.1 Specifications ....... . . 138 6.2 Points to Note about Remote Power OFF and the Shutdown Function .
  • Page 138: Specifications

    Chapter 6 Technical Information Knowledgebase 6.1 Specifications The Management Blade is installed to the chassis by default. Specifications are as follows. Parameter Functions and Specifications Product name Management blade LAN (10BASE-T/100BASE-TX) × 1, Serial × 1 External interface Dimension (Length × Width × Height) 275 ×...
  • Page 139: Function

    PRIMERGY BX600 Management Blade Hardware Guide 6.2 Points to Note about Remote Power OFF and the Shutdown Function The following are points to note about remote power off and the shutdown function. 6.2.1 Remote Power OFF This is a function in Management Blade that remotely turns OFF the power of the chassis and Server Blade from the Web UI or CLI.
  • Page 140: Other Notes

    Chapter 6 Technical Information Knowledgebase 6.3 Other Notes The following are points to note when using Management Blade. ■ Notes on the event logs recorded when the power cable is unplugged When unplugging the power cable from the chassis, the following Management Blade event log will be recorded, but because the log is caused by unplugging the power cable, please ignore it.
  • Page 141 PRIMERGY BX600 Management Blade Hardware Guide Index Adding users....30, 113 LAN active LED ..... .11 Alarm handler .
  • Page 142 System fan unit ... . . 10, 28, 36, 82 Telnet ......64 Set .
  • Page 143 PRIMERGY BX600 Management Blade Hardware Guide B7FH-5611-01ENZ0-00 Issued in August, 2008 Issued by FUJITSU LIMITED • The contents may be revised without prior notice. • Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

Table of Contents