PRIMERGY BX600 S3 Hardware Manual page 35

Blade server system
Table of Contents

Advertisement

Display/Parameter
System Power Supply
Redundancy Mode
Power Supply Live Time
Counter
Component Name
Installation Date
Life Time
Expiry Date
Running time
Expiry Reporting Date
Status
Contact Check Box
Apply
Reset
Server Blade Power
Switch
Turning on the main power supply of the chassis starts the Network Blade and the system
fan operations. Power will be distributed to the Server Blade, but the Server Blade will not
be booted until a separate order to turn power ON is ordered.
• UPS
Not normally used. Do not set.
PRIMERGY BX600 Management Blade Hardware Guide
This item only appears when four power supply units are installed.
Sets the system power supply redundancy mode.
• 3+1: If one of four PSUs is failed, the system can be operated with the other
three.
This setting value is not supported.
• 2+2: If two of four PSUs are failed, the system can be operated with the other
two.
Indicates and sets the information about replacing the PSU and dummy PSU.
Displays the names of PSU installed in PSU slots 1 - 4.
Inputs the installation date of the PSU/dummy PSU.
Inputs the life time of PSU/dummy PSU (35,000h - operation time) when the PSU is
replaced.
It is measured in units of hours (hrs).
After replacing PSU/dummy PSU, click [Reset].
Displays the expiry date of the PSU/dummy PSU.
Displays the running time of the PSU/dummy PSU.
Displays the date when "Contact Check Box" is checked.
Displays the status of the PSU/dummy PSU.
When the life time of the PSU/dummy PSU is over, check the check box after
contacting a service representative.
When [Reset] is clicked it is unchecked.
Applies the input information.
Resets after erasing the information of "Running Time", "Expiry Reporting Date", and
"Contact Check Box".
Sets the power supply of all the installed Server Blades.
• Turn on all Server Blades: all the installed Server Blades are turned on sequentially.
• Turn off all Server Blades: Select this item and click [Apply] and the confirmation
screen appears. If [YES] in the confirmation screen is clicked, "graceful shutdown
and off" will be ordered for the "Power Status" of all the installed Server Blades (For
details about "Power Status", refer to "• Power Status / Power Switch" ( p.57)).
Important:
When performing Server Blade power set in this item, after ordering
power ON/OFF, check that all power ON/OFF operations have been
completed by icons on Web UI etc., and then move on to the next
operation.
Description
35