Parameter
2. NTP Server IP
The Lastest Sync Date/Time
4. Sync Mode
• 2. NTP Server IP (1_1_17_2)
Enter the IP address of the NTP server.
+------------------------------------------+
|
NTP Server IP
+------------------------------------------+
(1) NTP Server IP 1 : 0.0.0.0
(2) NTP Server IP 2 : 0.0.0.0
Enter selection or type (0) to quit:
Parameter
1. NTP Server IP 1
2. NTP Server IP 2
If an incorrect IP address is entered, time synchronization cannot be performed.
PRIMERGY BX600 Management Blade Hardware Guide
Setting
-
Enter the IP address of the NTP server.
"• 2. NTP Server IP (1_1_17_2)" (p.79)
-
This displays the latest time at which Management Blades
and NTP server time synchronization was performed.
Important:
When NTP has been enabled, always check whether the time
synchronization is being performed in this display. Because straight
after setting, it sometimes takes time to display this, click the page
reload button a few times and check the display.
Sync Afterward
Specify the time synchronization mode.
Sync Always
• Sync Afterward
The time of the Management Blade is synchronized to the
time of the NTP server only when the time of the NTP
server is faster.
When using this for operations that demand time to be
taken into careful consideration such as databases, select
this mode.
• Sync Always
The time of the Management Blade is synchronized with
the NTP server every 15 minutes.
page_1_1_17_2
Enter the IP address of the primary NTP server.
Enter the IP address of the secondary NTP server.
Contents
|