PRIMERGY BX600 S3 Hardware Manual page 85

Blade server system
Table of Contents

Advertisement

Parameter
5. System Power supply
Redundancy Mode
• 4. System Power Supply Unit Table (1_3_2_4)
Displays the status of the PSUs installed.
+------------------------------------------+
|
System Power Unit Status Table
+------------------------------------------+
(1) Power Supply Unit 1 : **
(2) Power Supply Unit 2 : **
(3) Power Supply Unit 3 : **
(4) Power Supply Unit 4 : **
Enter selection or type (0) to quit:
Parameter
System Power Supply Unit 1 -
System Power Supply Unit 4
PRIMERGY BX600 Management Blade Hardware Guide
Setting
3+1
This item only appears when four power supply units are
2+2
installed.
Sets the system power supply redundancy mode.
• 3+1: If one of four PSUs is failed, the system can
• 2+2: If two of four PSUs are failed, the system can
page_1_3_2_4
Displays the status of each PSU. If the PSU number is selected, more detailed
information is displayed.
"• System Power Supply Unit Table (1_3_2_4_1)" (p.86)
Contents
be operated with the other three.
This setting value is not supported.
be operated with the other two.
|
Contents
85