PRIMERGY
PRIMERGY RX200
Server System
Operating Manual
Xenia Fierley
Fujitsu Siemens Computers GmbH München
81730 München
e-mail: email: manuals@fujitsu-siemens.com
Tel.: (089) 61001--157
Fax: (++49) 700 / 372 00000
A26361-K878-Z102-2-7619
Sprachen: De
Edition April 2004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RX200 and is the answer not in the manual?

Questions and answers

Summary of Contents for PRIMERGY RX200

  • Page 1 PRIMERGY PRIMERGY RX200 Server System Operating Manual Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001--157 Fax: (++49) 700 / 372 00000 A26361-K878-Z102-2-7619 Sprachen: De Edition April 2004...
  • Page 2: Copyright And Trademarks

    Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Fax forms for sending us your comments are included in the back of the manual. There you will also find the addresses of the relevant User Documentation Department.
  • Page 3 Introduction Installation Steps Overview Important Notes Hardware Installation Preparation for Use and Operation Property and Data Protection Troubleshooting and Tips Abbreviation, Related Publications and Index...
  • Page 5: Table Of Contents

    Contents Introduction ......1 Overview of the Documentation ....1 Features .
  • Page 6 Hot-Swap HDD Modules ..... 47 5.4.1 Handling Hard Disk Drives/HDD Modules ... . 48 5.4.2 Installing/Removing HDD/Dummy Module .
  • Page 7: Introduction

    The optional RemoteView Service Board (RSB) enhances this functionality. Security functions in the BIOS Setup („D1570 Setup Utility for RX200“) and on the system board protect the data on the server against manipulation. Additional security is provided by the lockable rack door.
  • Page 8 – Technical Manual for the system board D1570 (PDF file available on the ServerBooks CD) – „D1570 Setup Utility for RX200“ (PDF file available on the ServerBooks CD) – “ServerStart Bundle“ includes the ServerStart CD, the ServerBooks CD and the print version of the manual „ServerStart Bundle“. The PDF file of the manual is also available on the ServerBooks CD.
  • Page 9: Features

    The features of the system board (D1570) are described in the technical manual for the system board in relation to the hardware and in the „D1570 Setup Utility for RX200“ (see “Related Publications” on page 69). Hard disk drives The server can accommodate up to three ULTRA 160-SCSI hard disk drive modules.
  • Page 10 Siemens. PDA reports the threat of a system error or overloading early on so that preventative measures can be taken. ServerView enables the management of all PRIMERGY servers in the network via a central console. The following key features are supported among others by ServerView in this context.
  • Page 11 The flash EPROM program supplied with the Fujitsu Siemens Computers utilities supports a fast BIOS update. The RemoteView Remote Test and Diagnosis System allows the PRIMERGY RX200 Server to be maintained from remote locations. Remote diagnosis can be performed as a result for system analysis, remote configuration and remote restart should the operating system or hardware fail.
  • Page 12: Notational Conventions

    RemoteView RemoteView is the remote management solution from Fujitsu Siemens Computers for Intel-based PRIMERGY systems. RemoteView and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operability in the event of errors.
  • Page 13: Technical Data

    Introduction Technical Data Technical Data Electrical data (power supply unit) Power supply unit Multi-range Rated voltage range 100 V- 127 V / 200 V - 240 V Frequency 50 Hz - 60 Hz Max. rated current: 3,5 A / 100 V -127 V 2,0 A / 200 V - 240 V Effective power 322 W...
  • Page 14 Technical Data Introduction Mechanical values Width 430 mm Installation depth 650 mm area for cable routing (cable area depth) in the rack 100 mm Height 44.2 mm or 1 HU Weight 13 - 15 kg (depending on the configuration) Ventilation clearance at least 200 mm on the front and on the rear side Environmental conditions Environment class 3K2...
  • Page 15: Installation Steps: Overview

    Installation Steps: Overview In this chapter you will find an overview of the steps necessary to install your server system. Links guide you to sections where you can find more detailed information on the individual steps: Ê At first, please take notice of chapter “Important Notes” on page 11and following.
  • Page 16 A print version of the ServerStart manual is included in the ServerStart Bundle, delivered with the server system. A PDF version of the manual is contained on the PRIMERGY ServerBooks CD. A26361-K878-Z102-2-7619...
  • Page 17: Important Notes

    Important Notes In this chapter you will find essential information regarding safety when working with your server. Safety The following safety notes are also provided in the “Safety and Ergonomics” manual, which contains additional information about ergonomics. This device complies with the relevant safety regulations for data processing equipment, including electronic office machines for use in an office environment.
  • Page 18 Safety Important Notes Before operating the device CAUTION! During installation and before operating the device, observe the instructions on environmental conditions for your device (see “Environmental conditions” on page 8). If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine.
  • Page 19 Important Notes Safety CAUTION! Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the central processing unit is still running but the peripheral device (e.g. storage subsystem) has failed during a power outage. Data and signal cables must be adequately shielded.
  • Page 20 Safety Important Notes CAUTION! The warranty expires if the device is damaged during the installation or replacement of system expansions. Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expan- sions, you may damage the system or violate the safety regulations and regulations governing RFI suppression.
  • Page 21 Important Notes Safety note about the laser The CD/DVD-ROM drive contains a laser diode classified according to IEC 825-1:1993:LASER CLASS 1. Batteries CAUTION! Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board).
  • Page 22 Safety Important Notes Modules with electrostatic-sensitive components Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: Remove the power plug from the power socket before inserting or removing components containing ESDs.
  • Page 23: Ce Certificate

    Important Notes CE Certificate CE Certificate The shipped version of this device complies with the requirements of the EEC directives 89/336/EEC „Electromagnetic compatibility“ and 73/23/EEC „Low voltage directive“. The device therefore qualifies for the CE certificate (CE=Communauté Européenne). FCC Class A Compliance Statement If there is an FCC statement on the device, then: The following statement applies to the products covered in this manual, unless otherwise specified herein.
  • Page 24: Transporting The Server

    Transporting the Server Important Notes specified by Fujitsu Siemens Computers. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices.
  • Page 25: Environment Protection

    Important Notes Environment Protection Environment Protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu Siemens Computers standard for “environmentally friendly product design and devel- opment”. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of disassembly and recycling have been taken into account.
  • Page 26 Environment Protection Important Notes Returning, recycling and disposal For details on take-back and reuse of devices and consumables within Europe, contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling center in Paderborn: Fujitsu Siemens Computers Recycling Center D-33106 Paderborn Tel.
  • Page 27: Hardware Installation

    Hardware Installation CAUTION! Please note the safety instructions in chapter “Important Notes” on page 11. Do not expose the server to extreme environmental conditions (see “Environmental conditions” on page 8). Protect it from dust, humidity, and heat. The HDD modules installed in the server may not be exposed to a temperature shock (see section “Handling Hard Disk Drives/HDD Modules”...
  • Page 28: Installation Steps

    Installation Steps Hardware Installation Installation Steps The following installation steps are described in detail in other sections of this chapter: Ê Unpacking the server (see next section “Unpacking the Server” on page 22). Ê Mounting the server into the rack (see the layout arrangement created with System-Architect on the order lists and section “Installing/Removing the Server into/from the Rack”...
  • Page 29: Installing/Removing The Server Into/From The Rack

    The rack systems of the Fujitsu Siemens Computers (PRIMECENTER Rack, DataCenter Rack and 19-Inch (Classic) Rack) support fully the installation of the PRIMERGY server systems. The installation into the at present usual rack systems of different foreign manufacturers (3rd-Party Rack) is supported to large part.
  • Page 30 19-inch installation level area for cable routing (cable area depth) and ventilation area for front panel and ventilation right and left area for support systems PRIMERGY installation depth front left support upright front right support upright rear left support upright...
  • Page 31 Hardware Installation Installing/Removing the Server into/from the Rack – The operability of the safety mechanisms at the server e.g. stoppers or holding back systems must be guaranteed. – The form of the rack support uprights must ensure the frontal screwing on of the rails.
  • Page 32 Installing/Removing the Server into/from the Rack Hardware Installation Figure 2: Mechanical conditions A26361-K878-Z102-2-7619...
  • Page 33: Necessary Parts

    Hardware Installation Installing/Removing the Server into/from the Rack 4.3.2 Necessary parts For mounting the server into the appropriate rack the following parts are available (figure 3 and/or figure 4): – support bracket (a) – one left and one right telescopic rail (a/b) (assembled) –...
  • Page 34: Preparing The Server

    Installing/Removing the Server into/from the Rack Hardware Installation 4.3.3 Preparing the Server Figure 5: Unlocking the telescopic bar Ê Open one of the telescopic rails completely. Ê Unlock the outermost telescopic bar by pushing the white lever (figure 5) in the direction of the arrow (1) and pull the telescopic bar completely out from the rail.
  • Page 35: Mounting In The Primecenter/Datacenter Rack

    Hardware Installation Installing/Removing the Server into/from the Rack 4xM4 Figure 6: Screwing this part of the rail onto the server Ê Place the u-shaped telescopic bars with the flat side on the left and/or on the right on the server. Ensure that the white lever is placed in the direction of the server front (1).
  • Page 36 Installing/Removing the Server into/from the Rack Hardware Installation Figure 7: Mounting the support bracket Ê Place the plugwashers in the holes of the support uprights and secure the bracket with two screws. Placing the plugwashers To fasten the telescopic rails, no flange nuts are necessary since the rails are equipped with threaded holes.
  • Page 37 Hardware Installation Installing/Removing the Server into/from the Rack Length adjustment of the rails Figure 9: Performing adjustment Ê Open the telescopic rails completely. Ê Release the both adjustment screws (1). Ê On the external side of the rails, there are two punched arrows. Set these arrows (2) with the center of the adjustment screws (1) to coincide.
  • Page 38 Installing/Removing the Server into/from the Rack Hardware Installation 2xM5 2xM5 Figure 11: Mounting the left telescopic rail Ê There is a small horizontal lead (1) between the securing holes on the rear end of the left telescopic rail. Fit this lead in the corresponding hole of the support bracket.
  • Page 39: Mounting Into The Classic Rack

    Hardware Installation Installing/Removing the Server into/from the Rack 4.3.5 Mounting into the Classic Rack General information are provided in the Technical Manual for the Classic (19-inch) Rack (see also “Related Publications” on page 69). Ê Mark the position of the attachment points for the telescopic rails and for the server (front panel) on the support uprights.
  • Page 40: Installing The Server

    Installing/Removing the Server into/from the Rack Hardware Installation Ê Repeat the steps with the right telescopic rail (to be mounted on the right support uprights). Ê Mount the server (see section “Installing the Server” on page 34). 4.3.6 Installing the Server Ê...
  • Page 41: Mounting In 3Rd-Party Racks

    Hardware Installation Installing/Removing the Server into/from the Rack The server is removed in the reverse order. CAUTION! No cable management is available for the server! Before removing the server from the rack, all cables connected on the server must be unpluged from the sockets. Please note the instructions in section “Installing/Removing the Server into/from the Rack”...
  • Page 42: Connecting Devices To The Rack Model

    Connecting Devices to the Rack Model Hardware Installation Connecting Devices to the Rack Model The ports for external devices are on the rear of the server. You find an additional USB port (position 10 in figure 14) on the front of the server. Which additional ports are available on your server depends on the PCI boards installed.
  • Page 43: Connecting The Server To The Line Voltage

    Hardware Installation Connecting the Server to the Line Voltage Some of the devices that can be connected may require special drivers (see the documentation for the connected device). Ê Connect the desired devices to the server. Connecting the keyboard, mouse and monitor (if desired) Ê...
  • Page 44: Instructions On Connecting And Disconnecting Cables

    Connecting and Disconnecting Cables Hardware Installation Instructions on Connecting and Disconnecting Cables CAUTION! Be sure to read the documentation for the peripheral devices before connecting them. Do not connect or disconnect data cables during a thunderstorm. When removing a cable, always hold it by the plug. Never unplug a cable by pulling at the cable itself.
  • Page 45: Preparation For Use And Operation

    Preparation for Use and Operation CAUTION! Please note the safety instructions in chapter “Important Notes” on page 11. Switching the Server ON and OFF CAUTION! If after switching ON the server there is nothing but flickering stripes on the screen, switch the server OFF immediately (see section “Flickering Stripes on the Monitor Screen”...
  • Page 46 Switching the Server ON and OFF Preparation for Use and Operation Switching the server OFF Power-on indicator (position 7 in figure 16 on page 42) lights green. Ê Shut down the operating system in an orderly manner. Ê Press the ON/OFF button (position 6 in figure 16 on page 42) and/or send a corresponding control signal (see “Other ON/OFF options”...
  • Page 47: Configuring The Server And Installing The Operating System

    This section contains information about configuring the server and installing the operating system. Make sure that the energy saving functions are disabled in the BIOS Setup („D1570 Setup Utility for RX200“) during server operation. 5.2.1 Configuration with ServerStart With the ServerStart-CD provided, you can configure the server and install the operating system in a convenient manner.
  • Page 48: Operating And Indicator Elements

    Operating and Indicator Elements Preparation for Use and Operation Operating and Indicator Elements 5.3.1 The Front Figure 16 shows the operating and indicator elements on the front. ID button ON/OFF button ID indicator Power-on indicator Global Error indicator NMI button Drive access indicator Reset button Figure 16: The front...
  • Page 49 Preparation for Use and Operation Operating and Indicator Elements Operation elements ON/OFF button When the system is switched OFF, it can be switched ON again by pressing the ON/OFF button. When the system is operating, pressing the ON/OFF button will switch OFF the system. The ON/OFF button does not disconnect the server from the mains.
  • Page 50 Operating and Indicator Elements Preparation for Use and Operation Global Error indicator (orange) Does not light when the system is ok. No service incident or critical event has occurred. Flashes orange when a critical event has occurred. Users can check BIOS Setup, system- and eventlog or via ServerView for event details.
  • Page 51 Preparation for Use and Operation Operating and Indicator Elements Hard disk drive control indicators HDD Access HDD Fault Figure 17: HDD module: indicators HDD access green – lights: HDD in active phase – does not light: HDD inactive HDD FAULT (in conjunction with a RAID controller) orange –...
  • Page 52: The Rear Side

    Operating and Indicator Elements Preparation for Use and Operation 5.3.2 The Rear Side Indicators on the connection panel Figure 18: Connection panel: indicators LAN active indicator (green) Flashes green when a LAN transfer occurs. Does not light if there is no LAN connection available. Lights if there is LAN connection available.
  • Page 53: Hot-Swap Hdd Modules

    The ID indicator can also be activated via ServerView and its status reported to ServerView. Hot-Swap HDD Modules Up to three U160-SCSI hard disk drives can be installed in the PRIMERGY RX200 server. The hard disk drives are built on a carrier which allows defective drives to be replaced (hot-swap) or new drives to be added during operation.
  • Page 54: Handling Hard Disk Drives/Hdd Modules

    If this is not taken into account, existing data can be destroyed. The hard disk drives which can be ordered for the PRIMERGY RX200 are delivered as HDD modules which include the hard disk drive preinstalled in a carrier.
  • Page 55 Preparation for Use and Operation Hot-Swap HDD Modules Removing the dummy module Free slots are provided with a dummy module that must be removed before installing an additional HDD module. Figure 19: Unlocking dummy module Ê Press both tabs on the dummy module together (see figure 19 on page 49) until the locking mechanism disengages and remove the dummy module from the mounting location.
  • Page 56 Hot-Swap HDD Modules Preparation for Use and Operation Unlocking HDD module Figure 20: Unlocking HDD module Ê Open the locking mechanism by pressing the locking button (1). Ê Push the handle of the HDD module fully in the direction of the arrow. If the HDD modules are provided with a transport lock (1 in the next figure) remove these before you open the locking mechanism.
  • Page 57 Preparation for Use and Operation Hot-Swap HDD Modules Installing the HDD module CAUTION! The HDD module must be acclimatized in its operating environment for an acclimatization time. Temperature difference (°C) Minimum acclimatization time (operating environment/outside) (hours) Table 3: Acclimatization time for HDD module Figure 22: Installing the HDD module A26361-K878-Z102-2-7619...
  • Page 58 Hot-Swap HDD Modules Preparation for Use and Operation Ê Carefully push the HDD module into the empty location (1) until it stops. Ê Push the handle completely in the direction of the arrow (2) until the locking mechanism engages. Removing the HDD module CAUTION! The hot-swap function can only be performed if the RAID is configured appropriately.
  • Page 59: Cleaning The Server

    Preparation for Use and Operation Cleaning the Server Cleaning the Server CAUTION! Switch the server off and pull the power plug out of the grounded- contact power socket. Do not clean any interior parts yourself; leave this job to a service technician.
  • Page 61: Property And Data Protection

    „D1570 Setup Utility for Rx200“ security functions. BIOS Setup Security Functions The Security menu in „D1570 Setup Utility for Rx200“ offers you various options for protecting your data from unauthorized access. By combining these options you can achieve optimum protection for your system.
  • Page 63: Troubleshooting And Tips

    Troubleshooting and Tips CAUTION! Observe the safety information in the „Security and Ergonomics“ manual and in chapter “Important Notes” on page 11. If a problem occurs, try to resolve it as described: – in this chapter, – in the documentation for the attached devices, –...
  • Page 64: The Server Switches Itself Off

    The Server Switches itself OFF Troubleshooting and Tips The Server Switches itself OFF Server management has detected an error Ê Check the error list or the ErrorLog file in the ServerView program, and attempt to eliminate the error. Screen Remains Blank Monitor is switched off Ê...
  • Page 65: Flickering Stripes On The Monitor Screen

    Troubleshooting and Tips Flickering Stripes on the Monitor Screen Flickering Stripes on the Monitor Screen CAUTION! Switch off the server immediately. Risk of material damage. Monitor does not support the set horizontal frequency Ê Find out which horizontal frequency your monitor screen supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.
  • Page 66: Floppy Disk Cannot Be Read And/Or Written

    Floppy Disk Cannot be Read and/or Written Ê Check whether the write protection for the floppy disk is activated. Ê Check the entry for the floppy disk drive in „D1570 Setup Utility for Rx200“. Incorrect Time and/or Date Ê Set the time and/or date in the operating system or in „D1570 Setup Utility for Rx200“.
  • Page 67: Drives Are Reported As „Dead

    If the drive continues to be shown as defective, then replace it. 7.12 Error Messages on the Screen The meanings of the error messages are explained in the „D1570 Setup Utility for Rx200“ and in the documentation for the relevant components and programs on the PRIMERGY ServerBooks CD. A26361-K878-Z102-2-7619...
  • Page 69: Abbreviation

    Abbreviation Alternating Current ANSI American National Standard Institut ASR&R Automatic Server Reconfiguration and Restart BIOS Basic Input-Output System Baseboard Management Controller Cache Coherency Compact Disk CD-ROM Compact Disk-Read Only Memory Cylinder Head Sector CMOS Complementary Metal Oxide Semiconductor Communication Central Processing Unit Direct Current A26361-K878-Z102-2-7619...
  • Page 70 DIMM Dual Inline Memory Module Dual Inline Package Direct Memory Access Desktop Management Interface Errror Checking and Correcting Extended Capabilities Port EEPROM Electrically Erasable Programmable Read-Only Memory ElectroMagnetic Compatibility) Emergency Management Port Enhanced Parallel Port ElectroStatic Discharge Front Panel Controller Field Replaceable Unit Front Side Bus A26361-K878-Z102-2-7619...
  • Page 71 Global Array Manager Graphical User Interface Hard Disk Drive Hot-Swap Controller I²C Inter-Integrated Circuit Input/Output Intelligent Chassis Management Identification Intergrated Drive Electronics Interrupt Request Line Local Area Network Logical Block Address Liquid Crystal Display Logical Unit Number A26361-K878-Z102-2-7619...
  • Page 72 Low-Voltage Differential SCSI Multi Mode Faser Manually Retention Latch Non Maskable Interrupt NVRAM Non Volatile Random Access Memory Operating System Peripheral Component Interconnect Prefailure Detection and Analysing POST Power ON Self Test RAID Redundant Arrays of Independent Disks Random Access Memory Read-Only Memory Remote Service Board Real Time Clock...
  • Page 73 RTDS Remote Test- und Diagnose-System SAF-TE SCSI Accessed Fault-Tolerance Enclosures Single Bit Error Single Connector Attachment SCSI Small Computer System Interface Sensor Data Record SDRAM Synchronous Dynamic Random Access Memory System Event Log System Management Interrupt System Setup Utility SVGA Super Video Graphics Adapter Universal Serial Bus Video Graphics Adapter...
  • Page 75: Related Publications

    Related Publications PRIMERGY manuals are available as PDF file on the ServerBooks CD. The ServerBooks CD is part of the ServerStart Bundle delivered with each server system. The actual version of the necessary manuals can be downloaded free of charge from the Internet.
  • Page 77: Index

    Index connecting 3rd-Party Rack cables 38 installing in 35 external devices 38 requirements 24 connections mains 36 consumables 19 accessible drives control panel 42 CD-ROM 3 correcting error 57 DVD-ROM 3 floppy disk drive 3 acclimatization time 51 data manipulation 1 server 21 data protection 55 additional information sources 2...
  • Page 78 Index error Global Error display drifts 59 indicator 42, 44, 46 drive "dead" 61 graphics card 37 drive defective 61 floppy disk hard disk drive 3 cannot be read or written 60 carrier 47 no mouse pointer 59 handling 48 power-on indicator HDD module 47 does not light 57...
  • Page 79 57 meaning PRIMECENTER Rack of the symbols 6 installing in 29 Memory Scrubbing 4 requirements 24 model rating plate 22 PRIMERGY 5 monitor property protection 55 display drifts 59 mounting kit server 27 rack mouse requirements 23...
  • Page 80 Index reset button 42, 43 ports 36 routing cables 32 power-on indicator 43 property protection 55 removing 23 safety 11 reset button 42, 43 saving energy 19 routing cables 32 screen safety standards 7 error message 61 serial port (COM1) 36 flickering 59 standards 7 no display on screen 59...
  • Page 81 Index take-back devices 20 technical data 7 telescopic rail 33 plugwasher 30 transport damage 9, 22 troubleshooting, server 57 unpacking server 22 USB port 4 ventilation clearance 8 weight 8 weight 8 A26361-K878-Z102-2-7619...
  • Page 83 Comments Fujitsu Siemens Computers GmbH User Documentation 81730 München Suggestions Germany Corrections Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY RX200 Server System A26361-K878-Z102-2-7619...
  • Page 85 Comments Fujitsu Siemens Computers GmbH User Documentation 81730 München Suggestions Germany Corrections Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY RX200 Server System A26361-K878-Z102-2-7619...
  • Page 86 A26361-K878-Z102-2-7619...
  • Page 87 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Table of Contents