PRIMERGY Econel 230R S1 Server
Operating manual
Edition May 2007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Econel 230R S1 and is the answer not in the manual?

Questions and answers

Summary of Contents for PRIMERGY Econel 230R S1

  • Page 1 PRIMERGY Econel 230R S1 Server Operating manual Edition May 2007...
  • Page 2 Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@fujtsu-siemens.com. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to...
  • Page 3: Table Of Contents

    Connecting the server to the mains ....49 Notes on connecting/disconnecting cables ..50 Operating manual Econel 230R S1...
  • Page 4 Added drive reported as defective ....69 7.11 Error message on screen ....69 Operating manual Econel 230R S1...
  • Page 5 Index ........87 Operating manual Econel 230R S1...
  • Page 7: Introduction

    Internet server. Thanks to its highly developed hardware and software components, the PRIMERGY Econel 230R S1 server offers a high level of data security and availability. These include the ServerView Suite server management software, Prefailure Detection and Analysing (PDA) and Automatic Server Reconfigu- ration and Restart (ASR&R).
  • Page 8 – Technical manual for the system board D2440 (PDF file available on the ServerBooks DVD supplied) – “BIOS Setup” (PDF file available on the ServerBooks DVD supplied) – “PRIMERGY Econel 230R S1 Server Options Guide” (PDF file available on the ServerBooks DVD) The “Options Guide” describes the server expansion and modifi- cation options.
  • Page 9 – Manual for the remote testing and diagnostic system RemoteView – Documentation for boards and drives – Documentation for your operating system – Information files on your operating system (See also “Literature” on page 85.) Operating manual Econel 230R S1...
  • Page 10: Features

    (for further details see “Hot- plug hard disk drives” on page 71). If the server has the corresponding RAID configuration, HDD modules can also be exchanged during operation. Operating manual Econel 230R S1...
  • Page 11 The maximum length of the external cable are three meters. Power supply The server has a built-in power supply unit, which automatically sets itself to a mains voltage in the range 100 V - 127 V or 200 V - 240 V. Operating manual Econel 230R S1...
  • Page 12 In this way, the iRMC enables complete control of PRIMERGY servers, regardless of system status, and thus particu- larly the control of PRIMERGY servers that are in the "out-of-band" system status. By default, the service LAN port is assigned to the iRMC. However, you can also configure LAN port 2 as the service LAN port in the BIOS setup.
  • Page 13 Power supply of the iRMC via the system standby supply Full-coverage alarm management System Error and Event Log (SEL) reading and processing More information about the iRMC can be found in the "PRIMERGY ServerView Suite - integrated Remote Management Controller (iRMC)" manual (see “Liter- ature”...
  • Page 14 Fujitsu Siemens Computers. PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken. ServerView enables the management of all PRIMERGY servers in the network via a central console. The following key features are supported among others by ServerView in this context.
  • Page 15 With the iRMC (integrated Remote Management Controller) on the system board and the optional remote testing and diagnostic system, the PRIMERGY Econel 230R S1 server can also be maintained and serviced remotely. This enables remote diagnosis for system analysis, remote configuration and remote restart should the operating system or hardware fail.
  • Page 16 RemoteView RemoteView is the remote management solution from Fujitsu Siemens Computers for Intel-based PRIMERGY systems. RemoteView and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors.
  • Page 17: Notational Conventions

    CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. Operating manual Econel 230R S1...
  • Page 18: Technical Data

    GB 17625 Interference emissions EN 55022 class A Harmonic current EN 61000-3-2 Flicker EN 61000-3-3 Interference immunity EN 55024, EN 300386 CE marking Low Voltage Directive 73/23/EEC to EU directives (Product Safety) Electromagnetic Compatibility 89/336/EEC Operating manual Econel 230R S1...
  • Page 19 Condensation during operation must be avoided! Noise level Sound power level L (ISO 9296) < 5.9 B (standby) < 6.6 B (operation) Sound pressure level at adjacent workstation < 44.1 dB (A) (standby) (ISO 9296) < 50.7 dB (A) (operation) Operating manual Econel 230R S1...
  • Page 21: Installation Steps, Overview

    “Connecting the server to the mains” on page 49). Ê Make yourself familiar with the operating and indicator elements on the front and on the rear side of the server (see “Controls and displays” on page 51). Operating manual Econel 230R S1...
  • Page 22 The ServerStart disc supplied allows you to conveniently configure the server and install the operating system. Details on how to operate ServerStart, as well as some additional infor- mation, can be found in the “PRIMERGY ServerView Suite - ServerStart” manual. Configuration information can also be found in the “Configuration with...
  • Page 23: Important Information

    Any unauthorized opening and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability. Operating manual Econel 230R S1...
  • Page 24 This device must only be connected to properly grounded shock- proof sockets or insulated sockets of the rack's internal power supply with tested and approved power cables. Ensure that the device is connected to a grounded shockproof socket close to the device. Operating manual Econel 230R S1...
  • Page 25 (electric shock hazard, short circuit). In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team. Operating manual Econel 230R S1...
  • Page 26 Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center. Operating manual Econel 230R S1...
  • Page 27 The CD/DVD drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous. Never remove parts of the CD/DVD drive casing! Operating manual Econel 230R S1...
  • Page 28 All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant: Cd Cadmium Hg Mercury Pb Lead Operating manual Econel 230R S1...
  • Page 29 Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Operating manual Econel 230R S1...
  • Page 30: Ce Conformity

    Operating manual Econel 230R S1...
  • Page 31: Transporting The Server

    Do not unpack the server until it is at its installation location. If you need to lift or transport the server, ask other people to help you. Never lift or carry the device by the handles on the front panel. Operating manual Econel 230R S1...
  • Page 32: Notes On Installing In The Rack

    If the rack model is integrated into an installation that draws power from an industrial power supply network with an IEC309 type connector, the power supply's fuse protection must comply with the requirements for non-industrial power supply networks for the type A connector. Operating manual Econel 230R S1...
  • Page 33: Environmental Protection

    All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants: Cd Cadmium Hg Mercury Pb Lead Operating manual Econel 230R S1...
  • Page 34 Europe can also be found in the “Returning used devices” manual, via your local Fujitsu Siemens Computers branch or from our recycling center in Paderborn: Fujitsu Siemens Computers Recycling Center D-33106 Paderborn Tel. +49 5251 8 18010 +49 5251 8 18015 Operating manual Econel 230R S1...
  • Page 35: Hardware Installation

    (hours) Table 1: Acclimatization time table “Acclimatization time”, the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously (outside, transport or storage temperature). Operating manual Econel 230R S1...
  • Page 36: Unpacking The Server

    The product name and serial number of the product can be found on the identi- fication rating plate. Ê Notify your supplier immediately should you discover that the items delivered do not correspond to the delivery note. Operating manual Econel 230R S1...
  • Page 37: Installing/Removing The Server In/From The Rack

    Rack requirements The rack systems from Fujitsu Siemens Computers (PRIMECENTER Rack and DataCenter Rack) support installation of PRIMERGY servers. Installation in most current rack systems from other manufacturers (3rd party racks) is also supported. To accommodate the ventilation concept and ensure proper ventilation, any unused areas in the rack must be sealed using dummy covers.
  • Page 38 The mounting of the rails in the different racks is described in the next sections. Installation of the cable management is described in detail in the Technical Manual for the respective rack. For rack systems from other manufacturers: Operating manual Econel 230R S1...
  • Page 39 Rear 19” installation level Cable routing area (cable area depth) and ventilation Space for front panel and ventilation Space for right and left support systems PRIMERGY rack installation depth Front left support upright Front right support upright Rear left support upright Rear right support upright –...
  • Page 40 Installing/removing the server in/from the rack Hardware installation – Power supply: For installation in 3rd party racks, you must ensure that the appropriate socket strips are present. Figure 2: Mechanical requirements Operating manual Econel 230R S1...
  • Page 41: Installation In Primecenter/Datacenter Rack

    Figure 3: Fitting the support bracket Ê Position the support bracket at the corresponding height on the rear left support upright, (insert lug in corresponding hole) (1). Ê Secure the bracket with two screws incl. plug washers (2). Operating manual Econel 230R S1...
  • Page 42 Ê Press the release spring (2) and remove the server rail. Ê Repeat both steps with the second telescopic rail. No nuts are required to secure the telescopic rails as the fixing holes on the rails are threaded. Operating manual Econel 230R S1...
  • Page 43 Ê Insert the server (see the “Inserting the server” on page 45 section). Ê Route the cables once the server has been inserted, as described in the Technical Manual for the rack in question. Operating manual Econel 230R S1...
  • Page 44: Installation In 3Rd Party Racks

    Ê Secure the telescopic rails as described in section “Installation in PRIME- CENTER/DataCenter Rack” on page Ê Mount the server (see section “Inserting the server” on page 45) and route the cables as described in the rack manual. Operating manual Econel 230R S1...
  • Page 45: Inserting The Server

    Ê Place the server rails on the three screws on both sides of the server (1) and slide the server rails forwards to secure them (2). The safety spring (a) must engage with an audible click. Operating manual Econel 230R S1...
  • Page 46 Ê Gently push the server as far as it will go into the rack (4). Ê Fasten the server to the rack (5) using the two knurled screws (front panel). To remove the server, follow this procedure in reverse. Operating manual Econel 230R S1...
  • Page 47: Connecting Devices To The Server

    7 Monitor port (VGA) (blue) 3 Service LAN port 8 Serial port COM 1 (turquoise) (only available for certain variants (alternative service port) of the PRIMERGY Econel 230R S1) 4 LAN port 2 9 Keyboard port (PS/2) (purple) 5 LAN port 1 Some of the devices that can be connected may require special drivers (see the documentation for the connected device).
  • Page 48 Ê Connect the power cable of the monitor to the mains socket strip of the rack. The rated current for the monitor can be found on the technical data label on the monitor or in the operating manual for the monitor. Operating manual Econel 230R S1...
  • Page 49: Connecting The Server To The Mains

    Ê Connect the insulated connector on the power cord (1) to the server power supply. Ê Connect the mains connector (2) to an outlet on the rack's socket strip (see also Technical Manual for the rack). Operating manual Econel 230R S1...
  • Page 50: Notes On Connecting/Disconnecting Cables

    Ê Turn off all power and equipment switches. Ê Disconnect all power plugs from the grounded shockproof sockets. Ê Unplug all data communication cables from the utility sockets. Ê Disconnect the relevant cables from the server and all the peripherals. Operating manual Econel 230R S1...
  • Page 51: Starting Up And Operation

    Figure 11: Front of server — server variant with EasyChange hard disk drives 1 CD/DVD indicator 6 Global error indicator 2 ID indicator 7 Drive access indicator 3 Reset button 8 Power-on indicator 4 NMI button 9 ID button 5 On/Off button Operating manual Econel 230R S1...
  • Page 52 1 CD/DVD indicator 7 Drive access indicator 2 ID indicator 8 Power-on indicator 3 Reset button 9 ID button 4 NMI button 10 HDD BUSY indicator 5 On/Off button 11 HDD FAULT indicator 6 Global error indicator Operating manual Econel 230R S1...
  • Page 53 You can set the power up delay (in seconds) in the BIOS setup in the Server Menu menu with Power Cycle Delay . Lights up green when the server is switched on. Flashes green when the server has been switched on and is in standby mode. Operating manual Econel 230R S1...
  • Page 54 ID button. To deactivate, press the button again. The ID indicator can also be activated via ServerView and its status reported to ServerView. Indicators on the drives CD/DVD indicator Lights up green when the storage medium is being accessed. Operating manual Econel 230R S1...
  • Page 55 – Slow flashing: HDD Rebuild (the data is being restored after changing a hard disk drive) – Fast flashing: HDD Identify – four fast blinks/pause: HDD Predicted Fault – Two fast flashes/pause: HDD Hot Spare (Hot spare drive active. The corresponding drive has failed). Operating manual Econel 230R S1...
  • Page 56: Rear Of Server

    Flashes red when a critical event has occurred. Users can check BIOS Setup, system- and eventlog or via ServerView for event details. If the event is still acute after a power failure, the indicator is activated after the restart. Operating manual Econel 230R S1...
  • Page 57 4 LAN transfer rate indicator (standard LAN) Lights yellow for a LAN transfer rate of 1 Gbps. Lights up green for a LAN transfer rate of 100 Mbps. Does not light up for a LAN transfer rate of 10 Mbps. Operating manual Econel 230R S1...
  • Page 58: Switching The Server On And Off

    Ê Press the On/Off button (position 7 in figure 11 on page 51). The power-on indicator lights up green (item 10 in figure figure 11 on page 51). The server is switched on, performs a system test and boots the operating system. Operating manual Econel 230R S1...
  • Page 59 BIOS). – “Power override” function The server can be switched off immediately by pressing and holding the On/Off button (approx. 4-5 sec.). CAUTION! There is a risk that data may be lost. Operating manual Econel 230R S1...
  • Page 60: Configuring The Server

    Further information can be found in the "Integrated RAID for SAS User’s Guide" (on the ServerBooks DVD under "Controllers"). Descriptions of operating systems not covered in the RAID controller manual are provided in the appropriate readme files on the driver CDs. Operating manual Econel 230R S1...
  • Page 61: Configuration With Serverstart

    – Installation assistance for all leading server operating systems. – Creation of configuration files for unattended installation of several PRIMERGY servers with identical hardware configurations. – Installation of drivers and additional software. The software that can be installed depends on your server’s hardware configuration.
  • Page 62: Configuration Without Serverstart

    Clean the keyboard and the mouse with a disinfecting cloth. Wipe the server and monitor casing with a dry cloth. If particularly dirty, use a cloth that has been moistened in a mild domestic detergent and then carefully wrung out. Operating manual Econel 230R S1...
  • Page 63: Property And Data Protection

    Lock field in the Security menu. Preventing the system from booting from the floppy disk drive You can activate this protection by selecting the item Diskette Lock for the System Load field in the Security menu. Operating manual Econel 230R S1...
  • Page 64 To activate this protection, select the value Disabled for the Remote Power On field in the Security menu. Protecting the server from being switched off by a program To activate this protection select the value Disabled for the Soft Power Off field in the Security menu. Operating manual Econel 230R S1...
  • Page 65: Troubleshooting And Tips

    Power supply overloaded Ê Disconnect the server power plug(s) from the power socket(s). Ê Wait a few seconds before you plug it/them into the grounded socket(s) again. Ê Switch on your server. Operating manual Econel 230R S1...
  • Page 66: Server Switches Itself Off

    (if it is plugged in with a connector). If a separate graphics card is installed in the server, then the monitor cable must be connected to the gra- phics card. Ê Switch on the monitor and the server. Operating manual Econel 230R S1...
  • Page 67: Flickering Stripes On Monitor Screen

    Ê Check whether the mouse driver is properly installed and is activated when the application program is started. Detailed information can be found in the user manuals for the mouse, the operating system and the application pro- gram. Operating manual Econel 230R S1...
  • Page 68: Incorrect Date And Time

    The system will not boot after installing a new hard disk drive. SAS configuration incorrect Ê Check the settings for the hard disk drives (SAS Device Configuration) and the additional settings in the SAS configuration menu. Operating manual Econel 230R S1...
  • Page 69: Drives Reported As "Dead" When Starting System

    77). 7.11 Error message on screen The meaning of the error message is explained in the manual for the BIOS-Setup and in the documentation for the relevant components and programs on the PRIMERGY ServerBooks DVD. Operating manual Econel 230R S1...
  • Page 71: Hot-Plug Hard Disk Drives

    Up to six hot-plug hard disk drives can be installed in the PRIMERGY Econel 230R S1 Server. The hard disk drives which can be ordered for the PRIMERGY Econel 230R S1 are supplied already mounted in an installation frame so that defective hard disk drives can be replaced and new drives can be added during operation.
  • Page 72 Handle for locking and unlocking the HDD module Button for locking and unlocking the handle Ridge for the application of a sticker with the current drive name Dummy module Tabs for unlocking the dummy module Operating manual Econel 230R S1...
  • Page 73: Handling Hard Disk Drives And Hdd Modules

    Temperature difference (°C) Minimum acclimatization time (operating (hours) environment/outside) Table 2: Acclimatization times for HDD modules Always set the HDD module down carefully, with the large surface facing downwards to prevent it from tipping over. Operating manual Econel 230R S1...
  • Page 74: Removing/Installing The Dummy Module

    EMC regulations (regulations regarding electromagnetic compatibility), and for protection against fire. Ensure that the dummy module engages correctly in the slot. Operating manual Econel 230R S1...
  • Page 75: Installing/Removing The Hdd Module

    Figure 18: Unlocking the HDD module Ê Open the locking mechanism by pressing the locking button (1). Ê Push the handle of the HDD module fully in the direction of the arrow (2). The HDD module is now unlocked. Operating manual Econel 230R S1...
  • Page 76 Ê Carefully push the HDD module into the empty mounting location (1) until it stops. Ê Push the handle completely in the direction of the arrow (2) until the locking mechanism engages. Operating manual Econel 230R S1...
  • Page 77 This period is necessary for the RAID controller to recognize that an HDD module has been removed and for the hard disk drive to come to a stop. Ê Pull the HDD module out completely. Operating manual Econel 230R S1...
  • Page 78 EMC regulations (regulations regarding electromagnetic compatibility), and for protection against fire. Ensure that the dummy module engages correctly in the slot. Operating manual Econel 230R S1...
  • Page 79: Abbreviations

    Automatic Server Reconfiguration and Restart Advanced Technology Attachments BIOS Basic Input-Output System Baseboard Management Controller Cache Coherency Compact Disk CD-ROM Compact Disk-Read Only Memory Cylinder Head Sector CMOS Complementary Metal Oxide Semiconductor Communication Central Processing Unit Operating manual Econel 230R S1...
  • Page 80 Extended Capabilities Port EEPROM Electrically Erasable Programmable Read-Only Memory Elektrostatisch Gefärdete Bauteile (component are in danger of electro- static) Emergency Management Port Enhanced Parallel Port Elektromagnetische Verträglichkeit (electromagnetic compatibility) ElectroStatic Discharge (elektrostatische Entladung) Front Panel Controller Operating manual Econel 230R S1...
  • Page 81 Front Side Bus Graphical User Interface Hard Disk Drive Hot-Swap Controller I²C Inter-Integrated Circuit Input/Output Intelligent Chassis Management Identification Intergrated Drive Electronics Intergrated Mirroring Enhanced iRMC intergrated Remote Management Controller Interrupt Request Line Local Area Network Operating manual Econel 230R S1...
  • Page 82 Multi Mode Faser Manually Retention Latch Non Maskable Interrupt NVRAM Non Volatile Random Access Memory Operating System Peripheral Component Interconnect Prefailure Detection and Analysing POST Power ON Self Test RAID Redundant Arrays of Independent Disks Operating manual Econel 230R S1...
  • Page 83 SCSI Accessed Fault-Tolerance Enclosures Serial Attached SCSI SATA Serial ATA Single Bit Error Single Connector Attachment SCSI Small Computer System Interface SDDC Single Device Data Correction Sensor Data Record SDRAM Synchronous Dynamic Random Access Memory Operating manual Econel 230R S1...
  • Page 84 Abbreviations System Event Log System Management Interrupt System Setup Utility SVGA Super Video Graphics Adapter Universal Serial Bus Video Graphics Adapter Operating manual Econel 230R S1...
  • Page 85: Literature

    Literature PRIMERGY server manuals are also available as PDF files on the ServerBooks DVD. The ServerBooks DVD is part of the PRIMERGY ServerView Suite, which is supplied with every server. The current versions of the required manuals may be downloaded for free from the Internet as PDF files.
  • Page 86 [16] LSI SATA Software RAID User’s guide [17] Integrated Mirroring User’s guide [18] PRIMECENTER Rack Technical manual [19] DataCenter Rack Technical manual [20] 19-Zoll-Rack/19 inch rack Technical manual [21] PRIMERGY ServerView Suite RemoteView User manual Operating manual Econel 230R S1...
  • Page 87: Index

    Class A Compliance Statement Cleaning Electrical data keyboard Electromagnetic compatibility 18, monitor Electrostatic-sensitive devices mouse (ESD) server EMC directive Components EMC regulations 74, hardware Environment class software Environmental protection Configuration, server Configuring onboard SAS controller Operating manual Econel 230R S1...
  • Page 88 HDD FAULT ID 51, 52, 54, LAN link/activity Global Error, indicator 51, 52, 54, LAN transfer rate Graphics card on the connection panel 56, power on indicator 51, rear of device 56, Information material, additional Operating manual Econel 230R S1...
  • Page 89 Memory module, hot-spare this drive memory RAID functionality Memory scrubbing RAID level Monitor Rating plate display drifts Recycling devices no display Remote Storage Mouse port RemoteView 15, Mouse, no mouse pointer on Removing, server screen Replacing online Operating manual Econel 230R S1...
  • Page 90 Unauthorized access installing Unpacking, server noise level USB port removing front of device routing cables rear of device safety standards service technician Service switches itself off (error) switching off switching on technical data Operating manual Econel 230R S1...
  • Page 91 Index Ventilation clearance Weight Operating manual Econel 230R S1...
  • Page 93 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.