A    Configuration Sheets of Hardware
      Use this form to record the hardware configuration and various settings of your server.
B     Configuration Sheets of BIOS Setup Utility Parameters
        Use this form to record the settings of the BIOS Setup Utility.
C     Configuration Sheets of Remote management controller's Web interface
        Use this form to record the settings of the Remote Management Controller Web interface.
D     Table of System resource management
        The I/O port address that can be selected with various expansion cards is the following tables.
E     Design Sheet of the RAID configuration
        Use this form to record the definitions of the disk groups (or the physical packs) and the logical
        drives in the RAID configuration (array configuration).
F     Design Sheet
        Use this form to record the software settings.
G     Accident Sheet
        Use this form to record any failures that occur in your server.
1

Advertisement

Table of Contents
loading

Summary of Contents for PRIMERGY TX200 S3

  • Page 1 PRIMERGY TX200 S3 Configuration Sheets About this manual A    Configuration Sheets of Hardware       Use this form to record the hardware configuration and various settings of your server. B     Configuration Sheets of BIOS Setup Utility Parameters         Use this form to record the settings of the BIOS Setup Utility. C     Configuration Sheets of Remote management controller's Web interface         Use this form to record the settings of the Remote Management Controller Web interface. D     Table of System resource management         The I/O port address that can be selected with various expansion cards is the following tables. E     Design Sheet of the RAID configuration         Use this form to record the definitions of the disk groups (or the physical packs) and the logical         drives in the RAID configuration (array configuration). F     Design Sheet         Use this form to record the software settings. G     Accident Sheet         Use this form to record any failures that occur in your server.
  • Page 2 Product Names The following expressions and abbreviations are used to describe the product names used in this manual. Product names Expressions and abbreviations  PRIMERGY TX200 S3  This server, or server  Windows  Windows Server 2003 R2,  Microsoft® Windows Server® 2003 R2, Standard Edition  Standard Edition  2003  Windows Server 2003 R2,  Microsoft® Windows Server® 2003 R2, Enterprise Edition  Enterprise Edition  Windows Server 2003 ,  Microsoft® Windows Server® 2003 , Enterprise Edition  Enterprise Edition  Windows Server 2003, Standard  Microsoft® Windows Server® 2003, Standard Edition  Edition  Windows Server 2003 R2,  Microsoft® Windows Server® 2003 R2, Standard x64 Edition  Standard x64 Edition  Windows Server 2003 R2,  Microsoft® Windows Server® 2003 R2 , Enterprise x64 Edition  Enterprise x64 Edition  Windows Server 2003, Standard  Microsoft® Windows Server® 2003, Standard x64 Edition  x64 Edition  Windows Server 2003 ,  Microsoft® Windows Server® 2003 , Enterprise x64 Edition  Enterprise x64 Edition  Windows  Microsoft® Windows® 2000 Server  Windows 2000 Server  2000  Microsoft® Windows® 2000 Advanced Server  Windows 2000 Advanced Server  Microsoft® Windows Server® 2003 Service Pack  SP  Microsoft® Windows® 2000 Service Pack...
  • Page 3: Table Of Contents

    PRIMERGY TX200 S3 Configuration Sheets Contents A Configuration Sheets of Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  B Configuration Sheets of BIOS Setup Utility Parameters . . . . . . . . . . .  B.1 Parameters in the Main menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  B.2 Parameters in the Advanced menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  B.3 Parameters in the Security menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12 B.4 Parameters in the Server menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 C Configuration Sheets of Remote management controller's Web interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C.1 Parameters in the iRMC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15 C.2 Parameters in the Power On/Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15 C.3 Parameters in the Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16 C.4 Parameters in the Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 C.5 Parameters in the Server Management Information . . . . . . . . . . . . . . . . .  17 C.6 Parameters in the Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18 C.7 Parameters in the SNMP Trap Alerting . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 C.8 Parameters in the Email Alerting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  19 C.9 Parameters in the User Management . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20 C.10 Parameters in the BIOS Text Console . . . . . . . . . . . . . . . . . . . . . . . . . .  23 D Table of System resource management . . . . . . . . . . . . . . . . . . . . . . . . . E Design Sheet of the RAID configuration . . . . . . . . . . . . . . . . . . . . . . . . E.1 For PG-140F/140G(MegaRAID SAS 8300XLP) . . . . . . . . . . . . . . . . . . . .  25 E.2 For PG-142E3 (MegaRAID SCSI 320-2) . . . . . . . . . . . . . . . . . . . . . . . . . .  27 E.3 For Integrated Mirroring SAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  29 F Design Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
  • Page 4 A Configuration Sheets of Hardware A Configuration Sheets of Hardware Use this form to record the hardware configuration and various settings of your server. Check the ( ) of your server settings. ■3.5-inch Internal Options Installation 3.5 inch internal option Installed position Bay 1 ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB Bay 2 ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB Bay 3 ( ) 73.4 GB ( ) 146.8 GB...
  • Page 5 ■CPU Installation CPU Installed position ( ) Xeon Processor 5050/2x2MB (FSB667MHz) ( ) Slot 1 ( ) Slot 2 ( ) Xeon Processor 5110/4MB (FSB1066MHz) ( ) Slot 1 ( ) Slot 2 ( ) Xeon Processor 5130/4MB (FSB1333MHz) ( ) Slot 1 ( ) Slot 2 ( ) Xeon Processor 5160/4MB (FSB1333MHz) ( ) Slot 1...
  • Page 6: B Configuration Sheets Of Bios Setup Utility Parameters

    B Configuration Sheets of BIOS Setup Utility Parameters B Configuration Sheets of BIOS     Setup Utility Parameters Use this form to record the settings of the BIOS Setup Utility. If you have not changed the initial value, check the box of "The initial values have been unchanged". The initial values in the dotted frame can be changed. If you change any setting, put a check mark in the bracket of the ”Setting” column. Keep the values on the gray zones unchanged. Follow the procedure below to start the BIOS Setup Utility. When the following message appears on the screen during POST, press the [F2] key while the message is displayed. When POST is completed, the Main menu screen appears. <F2> BIOS Setup/ <F12> Boot Menu If the system starts before starting the BIOS Setup Utility, press the [Ctrl] + [Alt] + [Delete] keys simultaneously and restart the system. B.1 Parameters in the Main menu ( ) The initial values have been unchanged. Item Initial value Setting System Time: HH:MM:SS Displays/Sets present time. System Date: MM/DD/YYYY Displays/Sets present date.
  • Page 7: B.2 Parameters In The Advanced Menu

    B.1 Parameters in the Main menu ■Boot Option Submenu ( ) The initial values have been unchanged. Item Initial value Setting Boot Options POST Errors Halt On All Errors ( )No Halt On Any Errors Keyboard Check Enabled ( )Disabled SM Error Halt Disabled ( )Enabled Fast Boot: Disabled ( )Enabled...
  • Page 8 B Configuration Sheets of BIOS Setup Utility Parameters ■Peripheral Configuration Submenu ( ) The initial values have been unchanged. Item Initial value Setting Peripheral Configuration Serial 1: Auto ( )Disabled ( )Enabled ( )OS Controlled Serial Port1 Address: *1 3F8h,IRQ 4 ( )2F8h,IRQ 3 ( )3E8h,IRQ 4 ( )2E8h,IRQ 3 Serial Multiplexer: System ( )iRMC...
  • Page 9 B.2 Parameters in the Advanced menu ■PCI Configuration Submenu ( ) The initial values have been unchanged. Item Initial value Setting PCI Configuration > PCI SLOTS Configuration Links to PCI SLOTS Configuration submenu > PCI IRQ Configuration Links to PCI IRQ Configuration submenu ■PCI SLOTS Configuration Submenu (...
  • Page 10 B Configuration Sheets of BIOS Setup Utility Parameters ■PCI IRQ Configuration Submenu ( ) The initial values have been unchanged. Item Initial value Setting PCI IRQ Configuration PCI IRQ Line 1 : Auto ( )Disabled ( )IRQ3 ( )IRQ4 ( )IRQ5 ( )IRQ6 ( )IRQ7 ( )IRQ9 ( )IRQ10 ( )IRQ11 ( )IRQ12 ( )IRQ14 ( )IRQ15 PCI IRQ Line 2 : Auto...
  • Page 11 B.2 Parameters in the Advanced menu ■Advanced System Configuration Submenu ( ) The initial values have been unchanged. Item Initial value Setting Advanced System Configuration BIOS Work Space Location: Expansion ROM Area ( )Top of Base Memory Memory Redundancy: Disabled ( )Sparing CPU Mismatch Detection: Enabled ( )Disabled CPU Timeout Counter: Disabled...
  • Page 12: B.3 Parameters In The Security Menu

    B Configuration Sheets of BIOS Setup Utility Parameters ■IPMI Submenu ( ) The initial values have been unchanged. Item Initial value Setting IPMI SEL Load Displays percentage of stored SEL Clear System Event Log: Disabled ( )Enabled Event Log Full Mode: Overwrite ( )Maintain iRMC Time Sync: Enabled ( )Disabled >...
  • Page 13: B.4 Parameters In The Server Menu

    B.4 Parameters in the Server menu B.4 Parameters in the Server menu ( ) The initial values have been unchanged. Item Initial value Setting O/S Boot Timeout: Disabled ( )Enabled Action: Reset ( )Continue ( )Power Cycle Timeout Value: )[0〜100] ASR&R Boot Delay: )[1〜30] Power Cycle Delay: )[0〜15] Boot Retry Counter: )[0〜7]...
  • Page 14 B Configuration Sheets of BIOS Setup Utility Parameters ■Memory Status Submenu ( ) The initial values have been unchanged. Item Initial value Setting Memory Status Memory Module 1A Enabled ( )Failed*1 ( )Disabled *2 Memory Module 2A Enabled ( )Failed*1 ( )Disabled *2 Memory Module 3A Enabled ( )Failed*1 ( )Disabled *2 Memory Module 1B Enabled ( )Failed*1 ( )Disabled *2...
  • Page 15: C Configuration Sheets Of Remote Management Controller's Web Interface

    C.1 Parameters in the iRMC Information C Configuration Sheets of Remote    management controller's Web interface Use this form to record the settings of the Remote Management Controller Web interface. If you have not change the initial value, check the box of "The initial values have been unchanged". The initial values in the dotted frame can be changed. C.1 Parameters in the iRMC Information ( ) The initial values have been unchanged. Item Initial value Setting iRMC Information Displays iRMC information. SSL and SSH Certificate Certification for SSL&SSH Certificate Upload Not Upload )Not Upload )Upload License Key...
  • Page 16: C.3 Parameters In The Fans

    C Configuration Sheets of Remote management controller's Web interface C.3 Parameters in the Fans ( ) The initial values have been unchanged. Item Initial value Setting Fan Test Sets Fan Test time. Fan Check Time 23:00 ] HH:MM Analog Fans Sets the operation at the Fan malfunction. 0 FAN1 CPU1 continue )shutdown-and-power-off Deley[ ]sec...
  • Page 17: C.5 Parameters In The Server Management Information

    C.5 Parameters in the Server Management Information C.5 Parameters in the Server Management Information ( ) The initial values have been unchanged. Item Initial value Setting Boot Options Sets the boot options . Error Halt Settings BIOS setting is )Continue )Halt on errors reflected Last Power On Reason: Displays trigger for power-on.
  • Page 18: C.6 Parameters In The Network Settings

    C Configuration Sheets of Remote management controller's Web interface C.6 Parameters in the Network Settings ( ) The initial values have been unchanged. Item Initial value Setting Ethernet MAC Address Displays MAC address of iRMC. IP Address BIOS setting is reflected Subnet Mask BIOS setting is reflected Gateway BIOS setting is reflected DHCP BIOS setting is...
  • Page 19: C.7 Parameters In The Snmp Trap Alerting

    C.7  Parameters in the SNMP Trap Alerting C.7 Parameters in the SNMP Trap Alerting ( ) The initial values have been unchanged. Item Initial value Setting SNMP Trap Destination SNMP Community public SNMP Server1 0.0.0.0 SNMP Server2 0.0.0.0 SNMP Server3 0.0.0.0 SNMP Server4 0.0.0.0 SNMP Server5 0.0.0.0 SNMP Server6 0.0.0.0 SNMP Server7...
  • Page 20: C.9 Parameters In The User Management

    C Configuration Sheets of Remote management controller's Web interface C.9 Parameters in the User Management ( ) The initial values have been unchanged. Item Initial value Setting iRMC User Information ID/Name 2 admin 2   [ The User Name is displayed that is created by [New User]. Clicking "UserName" displays a setting window for each UserName. The default settings or the settings that are configured when creating a new user are displayed on the setting window.
  • Page 21 C.9  Parameters in the User Management ■User "nnnnnn(2)" Configuration ( ) The initial values have been unchanged. Item Initial value Setting Access Information User Enabled Enabled )Disabled )Enabled Name admin Password *Displays Confirm Password *Enter the password again to confirm it. Privilege / Shell LAN Privilege )User ( )Operater ( )Administorator...
  • Page 22 C Configuration Sheets of Remote management controller's Web interface ■ User "    ( )" Configuration ( ) The user is not newly created. Item Initial value Setting Access Information User Enabled Setting at creating )Disabled )Enabled a new user Name Setting at creating a new user Password Setting at creating *Displays a new user Confirm Password *Enter the password again to confirm it.
  • Page 23: C.10 Parameters In The Bios Text Console

    C.10  Parameters in the BIOS Text Console C.10 Parameters in the BIOS Text Console ( ) The initial values have been unchanged. Item Initial value Setting BIOS Console Redirection BIOS setting is Options reflected Console Redirection Enabled )Disabled  ( )Enabled Console Redirection Mode )Standard )Enhanced Console Redirection Port )Serial 1 )Serial 2 Serial Port Baudrate...
  • Page 24 D Table of System resource management D Table of System resource management The I/O port address that can be selected with various expansion cards is the following tables. ■I/O port addresses I/O port address (h) Product name Setup method | | | | | | | | | | | | | | | | | | | | | | | | Serial port 1 BIOS setup |...
  • Page 25: E Design Sheet Of The Raid Configuration

    E.1 For PG-140F/140G(MegaRAID SAS 8300XLP) E Design Sheet of the RAID configuration Use this form to record the definitions of the disk groups (or the physical packs) and the logical drives in the RAID configuration (array configuration). E.1 PG-140F/140G(MegaRAID SAS 8300XLP) ■Content of definition of the Disk Group Installation HDD model Disk group / Spare disk * HDD Slot / Bay name capacity ( )Disk group [0] (e.g.) PG-HDB75A 73.4GB ( )Spare disk ( )Disk group [0] (e.g.) PG-HDB75A 73.4GB ( )Spare disk ( )Disk group [ ]...
  • Page 26 E Design Sheet of the RAID configuration ■Content of definition of the Logical Drive Logical drive number Disk group number Logical drive RAID level Write policy (LD No.)* (DG No.)*2 capacity ( )RAID 0 ( )Write Through ( )RAID 1 (e.g.) LD : 0 DG : 0 34464 MB ( )Write Back ( )RAID 5 ( )Bad BBU ( )RAID 10...
  • Page 27: E.2 For Pg-142E3 (Megaraid Scsi 320-2)

    E.2   For PG-142E3 (MegaRAID SCSI 320-2) E.2 For PG-142E3 (MegaRAID SCSI 320-2) ■Content of definition of the Physical pack Installed PCI slot : (          ) HDD destination Physical pack Installation HDD model SCSI channel destination (Array) HDD Slot / Bay name capacity SCSI ID*2 / Spare disk *3 (CH)*1 ( )Physical pack [0] (e.g.) 0 CH : 0 ID : 0 PG-HDB75A 73.4GB...
  • Page 28 E Design Sheet of the RAID configuration ■Content of definition of the Logical Drive Installed PCI slot : (          ) Logical drive number Physical pack number Logical drive RAID level Write policy (LD No.)* (DG No.)*2 capacity ( )RAID 0 ( )RAID 1 ( )Write Through LD : 0 Array : 0 34464 MB (e.g.) ( )RAID 5 ( )Write Back ( )RAID 10 ( )RAID 0...
  • Page 29: E.3 For Integrated Mirroring Sas

    E.3 For Integrated Mirroring SAS E.3 For Integrated Mirroring SAS ■Content of Definition of the Logical Drive Installed PCI slot : (          ) Installation HDD model name HDD capacity Logical drive capacity HDD Slot / Bay (e.g.) 0 PG-HDB75A 73.4GB 34464 MB (e.g.) 1 PG-HDB75A 73.4GB 34464 MB...
  • Page 30: F Design Sheet

    F Design Sheet F Design Sheet     When setting up the server using ServerStart, select the setting values and check the     boxes below in advance to ensure setup is performed smoothly. F.1 RAID/Disk Wizard Parameters Setting ( ) Logical Drive View ( ) Mass Storage Controller View (The RAID configuration can be specified) ( ) RAID      ( ) SCSI Controller ( ) Fibrechannel    ( ) IDE When you select "RAID" with controller's type Configure RAID ( ) Automatically  ( ) Manually...
  • Page 31: F.2 Os Wizard (Windows 2003 Install Wizard)

    F.2 OS Wizard (Windows 2003 Install Wizard) F.2 OS Wizard (Windows 2003 Install Wizard) Parameters Setting Install Windows 2003 Password for Administrator account Computer Identification When selecting Windows Server 2003/R2 to install ( ) Windows Server 2003, Standard Edition ( ) Windows Server 2003, Standard Edition including SP1 ( ) Windows Server 2003, Enterprise Edition ( ) Windows Server 2003, Enterprise Edition with SP1 ( ) Windows Server 2003 R2, Standard Edition...
  • Page 32 F Design Sheet Parameters Setting User Name User Name Organization Computer Name Product-ID ― ― ― ― Display settings ( ) 640 * 480 ( ) 800 * 600  ( ) 1024 * 768 Resolution ( ) 1156 * 864 ( ) 1280 * 1024   ( ) 1600 * 1200 Vrefresh ( ) 60 ( ) 70 ( ) 72 ( ) 75 ( ) 80 ( ) 85 ( ) 100 ( ) 16 colors   ...
  • Page 33 F.2 OS Wizard (Windows 2003 Install Wizard) Parameters Setting (Continuation of Network protocol) Connection name Protocol binding to this ( ) TCP/IP ( ) NWIPX ( ) NetBEUI ( ) Apple Talk adapter ( ) DLC ( ) NetMon ( ) PPTP Use of DHCP ( ) Use DHCP (When TCP/IP selected) IP Address Subnet Mask...
  • Page 34 F Design Sheet Parameters Setting Software Components ( ) Install default Components Select installation method ( ) Install customized Components R2 Components Only when selecting R2 components to install ( ) Application Mode(ADAM) ( ) Claims-Aware Applications Active Directory ( ) Traditional Applications ( ) Federation Service ( ) Federation Service Proxy ( ) DFS Management...
  • Page 35 F.2 OS Wizard (Windows 2003 Install Wizard) Parameters Setting (Continuation of Software Components) Only when selecting component to install Application and utilities ( ) clipboard viewer ( ) Desktop Wallpaper ( ) Document Template ( ) Paint Accessories ( ) All available mousepointers ( ) Word pad ( ) Calculator ( ) Character Map Accessibility Wizard...
  • Page 36 F Design Sheet Parameters Setting FTP service property (Only when FTP service is selected) FTP site directory (Default - \Inetpub\Ftproot) WWW service property (Only when WWW service is selected) WWW server directory (Default - \Inetsrv\WWWroot) Terminal server property (Only when terminal server is selected) Terminal service ( ) Permit remote desktop during unattended setup Authorize the following access...
  • Page 37 F.2 OS Wizard (Windows 2003 Install Wizard) Parameters Setting Active Directory details setting (only when DNS is selected) Install Active Directory ( ) Install ( ) Create a domain in a new forest ( ) Additional domain controller of the existing domain Active Directory type ( ) Create a new child domain under the existing domain tree ( ) Create a new domain tree in the existing fores Database folder Log folder...
  • Page 38: F.3 Os Wizard (Windows 2000 Install Wizard)

    F Design Sheet F.3 OS Wizard (Windows 2000 Install Wizard) Parameters Setting Install Windows 2000 Password for Administrator Computer identification ( ) Windows 2000 Server ( ) Windows 2000 Server including SP4 ( ) Windows 2000 Advanced Server ( ) Windows 2000 Advanced Server including SP4 ( ) per Seat License mode ( ) per Server...
  • Page 39 F.3 OS Wizard (Windows 2000 Install Wizard) Parameters Setting Network protocol ( ) Auto-installation Installation method ( ) Install driver only Network protocol property (when auto-installation is selected) Connection name Protocol binding to this ( ) TCP/IP ( ) NWIPX ( ) NetBEUI ( ) Apple Talk adapter ( ) DLC ( ) NetMon...
  • Page 40 F Design Sheet Parameters Setting Software Components Select installation method ( ) Select component to install Only when selecting component to install ( ) (IIS) common component ( ) (IIS) online help ( ) FTP (File Transfer Protocol) server ( ) Internet service manager (HTML) ( ) Internet information service snap-in ( ) NNTP Service Service...
  • Page 41 F.3 OS Wizard (Windows 2000 Install Wizard) Parameters Setting SNMP details (only when SNMP is selected) Trap Community name Trap destination Security Send authentication trap ( ) Send Receivable community name Receive SNMP packet ( ) Receive from all hosts Host name (only when specified) Agent Contact Address ( ) Physical ...
  • Page 42: F.4 Application Wizard

    F Design Sheet F.4 Application Wizard Parameters Setting ( ) Windows 2000 service pack4 ( ) Windows Server 2003 service pack1 ( ) ServerView Installable applications ( ) DSNAP ( ) RAID Management Tool ( ) Broadcom Advanced Control Suite Userspecific Command (only when selecting additional software) ( ) Install selected application from Local CD Userspecific Command ( ) Install selected application from Remote Server...
  • Page 43: G Accident Sheet

    G Accident Sheet Name (Product ID)  □ PRIMERGY TX200 S3 (PG           )  OS  Environment LAN/WAN config.  DATE/TIME What did you do?, what message? etc.  Phase of accident Attached paper Yes / No...
  • Page 44 PRIMERGY TX200 S3 Configuration Sheets CA92276-5688-01 Issued on  January, 2007 Issued by  FUJITSU LIMITED  • The contents of this manual may be revised without prior notice.   • Fujitsu assumes no liability for damages to third party copyrights or other rights     arising from the use of any information in this manual.   • No part of this manual may be reproduced in any form without the prior written     permission of Fujitsu.