PRIMERGY BX600 S3 Hardware Manual page 58

Blade server system
Table of Contents

Advertisement

Chapter 4 Web UI
- Hard Power off
The Server Blade is forcibly turned off.
• Power On/Off
Sets the Server Blade scheduled operations. Orders for scheduled operations are given from the
Management Blade.
To perform scheduled operations everyday set the "On Time" and "Off Time" of "Everyday" and
click [Everyday].
Display/Parameter
On Time
Off Time
• Power Setting
Sets the operations to forcibly turn off the power supply if the "off" order in "Off Time" for Server
Blade fails. If the following checkbox is checked, power will be forcibly turned off after a
specified period of time from when "off" failed.
When power off fail, force power off after n minutes. (n can be 1-7 mins.)
• Boot Option, server blade n
Changes Server Blade boot order.
• Boot Option Selected
Sets the boot method for OS boot.
- normal
Sets the boot order of Server Blade to the default settings set in BIOS.
- pxe-lan-1 / pxe-lan-6
Sets LAN port 1 or 2 to the top priority of the Server Blade boot order and change so that it boots
in Preboot eXecution Environment (PXE).
- add-in-pci-lan-1 / add-in-pci-lan-2
Sets LAN port 1 or 2 installed in the expansion card slot module to the top priority of the Server
Blade boot order and change so that it boots in Preboot eXecution Environment (PXE).
• Set BIOS recovery flash bit
Not used. Do not set.
58
When ordering power on after ordering Server Blade power off, check that the power
has been turned off first.
• hour: minute: Sets the time when to turn on the Server Blade each day by
"hour: minute". Time should be set in a 24-hour clock format.
• disabled: Time to turn on is not set.
• hour: minute: Sets the time when to turn off the Server Blade everyday by
"hour: minute". Time should be set in a 24-hour clock format.
• disabled: Time to turn off is not set.
Important:
Since Server Blade turns off by ordering "off" from the Management
Blade, it is necessary to make various setting to Server Blades. When
using, refer to "6.2 Points to Note about Remote Power OFF and the
Shutdown Function" ( p.139). Do not set this item when performing
operations for Server Blades that are not supported, because there is a
fear that unexpected operations such as ACPI shutdown or power off
may occur.