7B1-68 AUTOMATIC TRANSMISSION (4 A / T)
D When shift solenoid valve (1) is connected to battery (2), confirm
that shift solenoid valve is open condition by blowing air (50 –
200 kpa, 0.5 – 2.0 kg/cm
shown in the figure.
D When shift solenoid valve (1) is not connected to battery (2), con-
firm that shift solenoid valve is close condition by blowing air (50
– 200 kpa, 0.5 – 2.0 kg/cm
shown in the figure.
D When TCC solenoid valve (1) is connected to battery (2), confirm
that shift solenoid valve is close condition by blowing air (50 –
200 kpa, 0.5 – 2.0 kg/cm
shown in the figure.
D When TCC solenoid valve (1) is not connected to battery (2), con-
firm that TCC solenoid valve is open condition by blowing air (50
– 200 kpa, 0.5 – 2.0 kg/cm
shown in the figure.
PRESSURE CONTROL SOLENOID VALVE
INSPECTION
Resistance Check
Measure resistance between pressure control solenoid valve (1)
terminals.
Pressure control solenoid valve resistance
Standard: 5.0 – 5.6 Ω (at 20_C (68_F))
2
, 7 – 28.5 psi) into solenoid valve as
2
, 7 – 28.5 psi) into solenoid valve as
2
, 7 – 28.5 psi) into solenoid valve as
2
, 7 – 28.5 psi) into solenoid valve as