VNA View Menus

Calibration Types

The Calibration Type list box provides the complete selection of available calibration types.
The MS20xxB compact VNA Master and the S412E LMR Master models are
two-port, 1-path vector network analyzers that allow S
with a single connection. Not all calibration types in the following list apply to the
MS20xxB VNA Master and the S412E LMR Master.
Note
The MS20xxC VNA Master models are full-reversing, two-port vector network
analyzers that allow reflection measurements from both ports and allow
transmission measurements in both directions (S
measurements) with a single connection.
This section describes all available calibration types.
The following list describes each calibration type:
• Full 2-Port (S
directions, and provides the most accuracy for two-port devices. It requires three
calibration components and a through-line.
• Full S
(Port 1) calibrates Port 1 for reflection measurements only. It requires three
11
calibration components.
• Full S
(Port 2) calibrates Port 2 for reflection measurements only. It requires three
22
calibration components.
• Full S
and S
11
requires six calibration components, three calibration components for each port.
• Response S
21
for S
measurements. It requires a through-line.
21
• Response S
12
S
measurements. It requires a through-line.
12
• Response S
21
normalization for both S
• Response S
11
reflection measurements only. It requires one short or open.
• Response S
22
reflection measurements only. It requires one short or open.
• Response S
11
for both ports for reflection measurements only. It requires two components: one short
or open for each port.
• 1P2P S
, S
11
21
measurements and S
and a through-line.
• 1P2P S
, S
22
12
measurements and S
and a through-line.
Vector Network Analyzer MG
, S
, S
, S
) calibrates both ports for measurements in both
11
21
12
22
(both Ports) calibrates both ports for reflection measurements only. It
22
(Transmission Response Forward Path) performs simple normalization
(Transmission Response Reverse Path) performs simple normalization for
and S
(Transmission Response Both Paths) performs simple
12
and S
21
(Reflection Response, Port 1) performs simple normalization for Port 1
(Reflection Response, Port 2) performs simple normalization for Port 2
and S
(Reflection Response, Both Ports) performs simple normalization
22
(1 Path, 2 Port Forward Path) calibrates Port 1 for reflection
measurements only. It requires three calibration components
21
(1 Path, 2 Port Reverse Path) calibrates Port 2 for reflection
measurements only. It requires three calibration components
12
PN: 10580-00289 Rev. K
measurements. It requires a through-line.
12
6-4 Calibration Menus
and S
measurements
11
21
, S
, S
, and S
11
21
22
12
6-37