Anritsu Field Master Pro Measurement Manual

Anritsu Field Master Pro Measurement Manual

High accuracy power meter option 19
Hide thumbs Also See for Field Master Pro:

Advertisement

Quick Links

Measurement Guide
High Accuracy Power Meter
MS2090A Field Master Pro™
MS2080A Field Master™
MS2070A Field Master™
High Accuracy Power Meter
Power Meter measurements require a supported Anritsu USB power sensor that is sold separately.
Notes
Not all instrument models offer every option or every measurement within a given option. Refer to
the Technical Data Sheet of your instrument for available options and supported measurements.
Anritsu Company
490 Jarvis Drive
Morgan Hill, CA 95037-2809
USA
Option 19
Part Number: 10580-00492
Revision: C
Published: January 2023
Copyright 2023 Anritsu Company

Advertisement

Table of Contents
loading

Summary of Contents for Anritsu Field Master Pro

  • Page 1 MS2070A Field Master™ High Accuracy Power Meter Option 19 Power Meter measurements require a supported Anritsu USB power sensor that is sold separately. Notes Not all instrument models offer every option or every measurement within a given option. Refer to the Technical Data Sheet of your instrument for available options and supported measurements.
  • Page 2 Anritsu Company. Export Management The Anritsu products identified herein and their respective manuals may require an Export License or approval by the government of the product country of origin for re-export from your country. Before you export these products or any of their manuals, please contact Anritsu Company to confirm whether or not these items are export-controlled.
  • Page 3: Table Of Contents

    Contacting Anritsu for Sales and Service ........
  • Page 4 Contents-2 PN: 10580-00492 Rev. C High Accuracy Power Meter MG...
  • Page 5: Chapter 1-General Information

    Chapter 1 — General Information Introduction This measurement guide covers the Anritsu High Accuracy Power Meter (Option 19) calibration and setup measurements. Instruments with Option 19 and an appropriate Anritsu power sensor can be used to make high accuracy power measurements. Related Manuals...
  • Page 6: Illustrations

    Calibration and Verification The instrument comes fully calibrated from the factory and there are no field-adjustable components. Anritsu recommends annual calibration and performance verification by local Anritsu service centers. Accredited calibration to ISO17025 and ANSI/NCSL Z540-1 are available and can include a calibration certificate, test report, and uncertainty data.
  • Page 7: Chapter 2-High Accuracy Power Meter (Option 19)

    Table 2-1 lists the Option 19 compatible with Anritsu power sensors. This chapter provides a general overview of the instrument and its user interface. The Anritsu power sensor is not included with Option 19. A high accuracy power sensor must be...
  • Page 8: High Accuracy Power Meter Gui Overview

    2-2 High Accuracy Power Meter GUI Overview High Accuracy Power Meter (Option 19) High Accuracy Power Meter GUI Overview This section illustrates the main graphical displays and SETUP menu presented for the high accuracy power meter. For a basic power measurement example, refer to Section 2-3 “General Measurement Setup”...
  • Page 9: Status Panel

    High Accuracy Power Meter (Option 19) 2-2 High Accuracy Power Meter GUI Overview Status Panel The status panel and features illustrated in this section are unique to the HIPM and to the particular measurement and view that is selected. Press the Chevron icon to collapse the status panel and view the corresponding minimized status panel.
  • Page 10: General Measurement Setup

    2-3 General Measurement Setup High Accuracy Power Meter (Option 19) General Measurement Setup Field Master Series instruments display the power values in both dBm and Watts, and offers the following measurement features: • Relative Power displays power changes with respect to a desired reference value in both dB and % (percent).
  • Page 11: Example Measurement Setup

    2-3 General Measurement Setup Example Measurement Setup This measurement example uses an Anritsu MA24106A power sensor and an attenuator for a high power measurement. 1. Connect the USB cable between the sensor and your instrument. When the sensor is connected, a notification in the top toolbar will identify the sensor model number.
  • Page 12: Amplitude Menu

    2-4 AMPLITUDE Menu High Accuracy Power Meter (Option 19) AMPLITUDE Menu EXTERNAL GAIN: Press this submenu key to toggle relative power On or Off. This measurement shows the relative level of the desired base power level input to your instrument. When ON, the message EXTERNAL LOSS: Press this submenu key to toggle relative power On or Off.
  • Page 13: Zero/Cal Menu

    High Accuracy Power Meter (Option 19) 2-6 ZERO/CAL Menu ZERO/CAL Menu ZERO: With no power applied to the sensor and pressed On, the sensor is set to zero. This is recommended when making power measurements below –20 dBm. CAL FREQUENCY: Sets the measurement frequency. The frequency value is sent to the power sensor to apply the appropriate calibration factor.
  • Page 14: Saving And Recalling Measurements

    2-9 Saving and Recalling Measurements High Accuracy Power Meter (Option 19) Saving and Recalling Measurements The Field Master Series can save measurement setups, native trace and CSV trace data, and screenshots. You can recall setup and native trace files. For other file operations such as copy, move, and directory management, refer to “File Management”...
  • Page 15: Recalling A Measurement

    High Accuracy Power Meter (Option 19) 2-9 Saving and Recalling Measurements Recalling a Measurement You can recall a saved setup and native trace measurement. When recalling a setup, the instrument setup and operating state will be restored as it was when the setup was saved. When recalling a trace measurement, the instrument setup and on-screen measurement data will be restored as it was when the trace data was saved.
  • Page 16: File Menu

    2-9 Saving and Recalling Measurements High Accuracy Power Meter (Option 19) FILE Menu SAVE AS: Opens the Save dialog to manually enter a file location, enter a file name, and to set the file type to be saved. Depending on the selected measurement, you can save the following: •...
  • Page 18 Anritsu Company 490 Jarvis Drive Anritsu utilizes recycled paper and environmentally conscious inks and toner. Morgan Hill, CA 95037-2809 http://www.anritsu.com...

This manual is also suitable for:

Field masterMs2070aMs2080aMs2090a

Table of Contents