7-4 Distance Menus

DTF Setup Menu

This menu is displayed when a DTF graph type is selected.
Key Sequence: Freq/Dist > More
DTF Setup
Cable Loss
Cable Loss: Press this soft key to set the cable loss coefficient from 0.000
dB/m to 5.000 dB/m. (The units are dB/ft if units are set to US units.)
#
Propagation Velocity: Press this soft key to set the fraction of propagation
Propagation Velocity
velocity from 0.001 to 1.000. For any fraction less than 1.000, press the
decimal key before entering the decimal digits.
#
Cable List: Press this soft key to open a list box and select a cable type. The
"Cable List Menu" on page 7-7
Cable List
through the list.
Windowing: Press this soft key to open the
Windowing
The window shape value is displayed on the key face, and may be
Rectangular, Nominal Side Lobe (as in this example), Low Side Lobe, or
Nominal Side Lobe
Minimum Side Lobe.
Back
Back: Press this soft key to return to the Dist/Freq menu.
Figure 7-5.
Field View DTF Setup Menu