6-3 Domain Setup Menus

Additional Dist Setup Menu (Waveguide)

Key Sequence: Freq/Time/Dist > Additional Dist Setup
Additional Dist Setup
Distance Info: Press this soft key to open the Distance Info List Box to find
helpful distance and parameter information. For a view of the list box
information, refer to
Distance Info
start and stop frequencies, start and stop distances, number of data points,
windowing and processing types, maximum distance, and distance resolution.
DUT Line Type
DUT Line Type
Coax
Waveguide
Coax Waveguide: Press this soft key to toggle the line type between
coaxial cable and waveguide.
Waveguide List
Waveguide List: Press this soft key to open a list box and select a
waveguide type. The Waveguide List menu provides quick navigation aids to
Cutoff Freq
search through the list.
# Hz
Waveguide Loss(dB/m)
Cutoff Freq: Press this soft key to set the cutoff frequency of the waveguide
#
that is in use.
Units
Waveguide Loss: Press this soft key to set the waveguide loss coefficient
m
ft
from 0.000 dB/m to 5.000 dB/m. (The units are dB/ft if units are set to US
units.).
Units
m ft: Press this soft key to toggle the units setting between metric units
Back
(meters) and US units (feet).
Back: Press this soft key to return to the
Waveguide List
Top
of
List
Page
Up
Page
Down
Bottom
of
List
Figure 6-10. Additional Dist Setup Menu (Waveguide)
6-12
Figure
6-12. The list box contains information such as the
PN: 10580-00289 Rev. K
VNA View Menus
"Distance Setup
Menu".