Bias Tee, Option 10
Figure 10-2
shows how the MS20xxC can provide an internal voltage between 12 volts and
32 volts that can be switched between Port 1 and Port 2. That voltage would be available at
the port along with the RF signals. Alternatively, an external voltage source could be
connected to the Bias Tee input ports in order to provide a bias voltage between +50 volts and
–50 volts at both ports simultaneously, if desired.
Figure 10-2. Internal or External Bias (MS20xxC shown)
Vector Network Analyzer MG
Port 1
Internal
Bias Tee
Source
PN: 10580-00289 Rev. K
External Bias Inputs
(±50 V, 500 mA Max)
Internal
Switch
Bias Tee
Internal Bias
+12 to +32 V
450 mA Max
Switch
10-3 How Bias is Generated
Port 2