Interface Connections; Software Functionality; Humidifier Pc Board: Led Descriptions - AGFA Avantra 36/44 Service Manual

Table of Contents

Advertisement

The voltage comparator is structured as an oscillator with the frequency controlled
by the sensor. This sensor, a capacitor, varies its capacitance in relation to the
amount of moisture in its environment. As the moisture level increases, the sensor
capacitance also increases causing the oscillator frequency to decrease.

2.15.5 Interface Connections

The controller module connects by cable to the imagesetter through the supply
sensor driver module (SSDM) board. The cable connects three humidifier functions
(sensing and controlling) to the SSDM.

2.15.6 Software Functionality

The humidifier option enables and disables via the operator contol panel (OCP)
configuration screen (also see user documentation). Pressing the humidifier icon on
this screen displays an expanded view of both the option's current and alternate
state (i.e., enabled or disable). The screen highlights (bold type) the current state.
When the humidifier option is not installed, the humidifier key shows the humidi-
fier disabled icon.
2.15.7 Humidifier PC Board: LED Descriptions
CR1
+24 V to the fan. LED "On" = module enabled
CR3
This LED should be on whenever power is applied to the humidifier PC
board.
CR7
This LED comes on when the water value solenoid is energized, opening
the water value and allowing the water reservoir to fill.
J1
CR1
Figure 2-21 Humidifier PC board, with connectors (J1 and J2)
CR3
and LED's (CR1, CR3, and CR7)
Section I: Imagesetter
J2
CR7
Functional Analysis 2-37