3. Remove the 3/8¨ hex bolt in the end stops at each side, left and right, of
the carriage. Refer to Figure 1-18.
1
Figure 1-18 Unlocking the carriage.
–One of 2 end stops (1 on each carriage end). –Center stop.
4. Remove the 3/8¨ screw in the center stop.
5. Power up the imagesetter, which makes the flappers lift. Remove the
foam pads from the right hand side of the imagesetter. Refer to Figure 1-
18.
6. When the carriage comes into the home position, remove the foam from
the left hand side of the system. Refer to Figure 1-18.
7. Shut off the imagesetter. Replace the light shields, left and right, and
close the left side cover.
8. Turn the system on and make sure that the cooling fans operate. Close
the right side cover.