4.4.2 Carriage Sensor Driver (CSDM) PCB

Tools Required: 3/16" nut driver, small screwdriver
Remove:
1. Turn the system off and unplug the power cord from the outlet.
2. Open the left and right side covers. See Section 4.2.1, Right/Left Side Cov-
ers.
3. Remove the inner light shields on the right side of the system, then the
light shield on the left side of the system. See Section 4.6.1, Light Shields
(Right and Left).
This accesses both sides of the carriage assembly.
4. On the right side of the system, disconnect the flex cable, LDM cable, SGM
sensors cable, SGM motors cable, digital encoder connector from the
CSDM PCB. Refer to Figure 4-19.
6
5
4
Figure 4-19 Carriage sensor driver module PCB (CSDM) (right side).
–LDM cable. –Flex cable connector. – CSDM PCB.
–SGM Sensor Connector. –SGM motor connector.
4-28 Removal and Replacement
3
2
1
–Digital encoder connector.