If the customer is setting up the optional on-line processor (OLP)/buffer as
well, the OLP electrical specifications are:
Volts:
Amp:
Rec.:
Phases:
Load:
Environment
The system should be located in a clean, static free work area for best
operation. The system must not be placed near heating or air conditioning
equipment. The customer must provide the proper work environment as
described in Work Space below. Environmental specifications for the imag-
esetter include:
Oper/Temp:
Humidity:
For absolute accuracy 70 ° F ± 3 ° (21 ° C ± 2 ° ).
Work Space
The system should be located in an area that allows enough surrounding
space to permit unrestricted air flow and service access. Approximately
three feet should be left on all sides. No overhead lights should appear
directly over the system. The system should not be located near windows
with direct sunlight. The floor where the Avantra 36/44 imagesetter is to
be placed must meet the industrial standard for weight per square foot (100
lbs/sq.ft.). Avantra's imagesetter physical specifications are:
Width:
Height:
Depth:
Weight:
1-2 Installation
230
30
NEMA L6-30P
1, 2 or 3 phases + (neutral) + ground
Maximum 7.0 kW
65 ° to 80 ° F (18 ° to 27 ° C)
45 to 55%, non-condensing
73" (185.42 cm)
48" (121.92 cm)
35" (88.90 cm)
1700 lbs. (771.11 kg)