Avantra 36/44 Service Manual
3. Plug the telephone line into the modem jack marked LINE. If desired, plug
the telephone into the modem jack marked PHONE.
4. Plug the power connector into the modem and plug the AC/DC adapter
into an AC outlet.
5. Depress the power switch on the modem to turn it on.
Ensure that the Power On/Ready LED on the modem illuminates. The
modem should now be ready for remote communication.
3.4.2.1
Making the Remote Connection
The following describes a typical remote session:
1. Ensure that the proper modem configuration and hardware connections
have been previously completed at the remote site (imagesetter).
2. Ensure that the proper modem configuration and hardware connections
have been completed at the PC.
3. Make a voice connection to the remote site prior to any remote connection
to the imagesetter. Call the customer on a telephone (other than the
modem line) and inform them you would like to make a remote connec-
tion to the Avantra. Make sure that the system is turned on, that all jobs
have been cleared from the drum, and that other users have been informed
not to send jobs to the Avantra.
4. Turn on the PC and start the Avantra Diagnostic Program. Type:
C:\avantra>avdiag
5. If the AVDIAG has been set up for remote communication on boot up, a
dialog box with a list of phone numbers to dial appears. If AVDIAG has
not been set up for remote communication, a time-out error appears sev-
eral times before allowing access to the main menu.
NOTE:
Pressing ESC during this time aborts the retries.
At this point, under Utilities, select Modem Functions then Dial-Out. The
dialog box with the list of phone numbers to dial appears.
6. Select the desired phone number and press RETURN.
The program begins the dial-out sequence.
7. After a connection has been made, press any key to continue.
This dismisses the dialog box.
8. Enter service mode 1 and get the system configuration.
NOTE:
If the manual dial-out feature was used to connect, entering
service mode will not be automatic. Select New Engine/
Restart under the Utilities menu to enter service mode.
3-66 Diagnostics