Avantra 36/44 Service Manual
4. Remove the hex screw securing the focus sensor to the bracket. Refer to
Figure 4-39.
1
Figure 4-39 Focus sensor location.
–Focus sensor.
5. Remove the sensor cable plug from the shell connector removed in Step 2.
Replace:
1. Reverse the removal procedure above.
2. Run the FOCUS.FIL file from the PC imager to check the focus adjustment.
4-56 Removal and Replacement