AGFA Avantra 36/44 Service Manual page 389

Table of Contents

Advertisement

Avantra 36/44 Service Manual
27. Install the filter housing for the developer without the cartridge installed.
Rinse each tank thoroughly with water. Put in the color coded overflow
tubes in each tank, as follows:
Red for developer
Blue for fixer
Grey for water
Refer to Figure 1-25.
28. Check that the overflow tubes are secure by tightening with a T-wrench.
29. Re-tighten all hose clamps.
30. Check that the valve at the bottom of the developer filter housing is closed
and the valves leading to and from the filter housing are open.
31. Fill each tank with water, up to overflow, and replace the rack covers.
1-30 Installation
Figure 1-25 Overflow supports and tubes.
–Overflow supports. –Overflow tubes.