Cpu-Olp - AGFA Avantra 36/44 Service Manual

Table of Contents

Advertisement

Avantra 36/44 Service Manual
3.3

CPU-OLP

The following describes how to remove and replace the OLP central processing
unit (CPU).
Tools Required: Phillips screwdriver, 1/4" nut driver
Remove:
1. Turn off and unplug the OLP.
2. Remove the top covers.
3. Remove the top back panel.
4. Pull the electronics box straight out on its rollers.
5. Remove the seven cable plugs at the rear of the box. Refer to Figure 3-2.
6. Remove all fourteen (14) standoffs at the rear of the box. Refer to Figure 3-2.
2
3
4
5
6
Figure 3-2 The electronics box with rear standoffs and connectors.
– CPU electronics box. –Seven connectors and fourteen standoffs.
–X503level and feedback. –X501 film sensors. –X502 Startbox. –X500
temperature sensor. –X400 RS232/CL. –X402 OLP Interface. –X400 ATB.
3-4 Removal and Replacement