Spot Generation Module (Sgm) - AGFA Avantra 36/44 Service Manual

Table of Contents

Advertisement

4. Reverse the removal procedure starting from Step 4 to complete spin motor
installation.
5. Turn the system on and launch the AVDIAG program from your PC.

4.6.3 Spot Generation Module (SGM)

Tools Required: Allen wrenches
Remove:
WARNING: Never hold the SGM module by the laser diode assem-
bly. Doing this could cause misalignment of the laser.
NOTE: Each new SGM comes with a sheet of paper that contains
the new polarizer, focus home positions, and beam com-
pressor number. These values must be entered in the DEC
machine parameters after the SGM is installed.
1. Remove the carriage assembly from the system. See Section 4.5, Carriage
Drive Removal/Replacement Procedures.
2. Remove the plastic cover over the SGM assembly.
3. Loosen the two (2) allen screws securing the spin motor bracket to the car-
riage casting.
4. Remove the spin motor and place it next to the carriage assembly.
5. Remove the motor, sensor, and laser diode cables from the SGM to the car-
riage board.
6. Remove the three (3) allen screws securing the SGM assembly to the car-
riage casting.
Section I: Imagesetter
Removal and Replacement 4-49