Minimum Space Requirements; Machine Level; Power Source - Ricoh B286 Service Manual

Table of Contents

Advertisement

Preparation
9.
Put the machine on a strong and level surface.
!
The floor must be able to support a load of more than 2.94 kPa (300 kgf/m2.
10. Do not install the machine in an area where there are frequent strong vibrations.

1.1.2 MINIMUM SPACE REQUIREMENTS

1.
Front: 1000 mm (40")
2.
Back: 600 mm (23")
3.
Right: 600 mm (23")
4.
Left: 600 mm (23")

1.1.3 MACHINE LEVEL

1.
Front to back: Not more than 5 mm from level
2.
Right to left: Not more than 0.15/1000 mm from level.

1.1.4 POWER SOURCE

!
This machine is provided with a circuit breaker that cuts the power supply to the
main machine in case of a current overload or short circuit. The machine must be
installed in a building where circuit breakers (and equivalent devices) can operate
properly.
1.
Input Voltage Level:
!
120V, 60 Hz, 15 A or more
B286/B289
1-2
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B289

Table of Contents