2. PREVENTIVE MAINTENANCE

2.1 PM TABLE

Key for the PM Table
A = Adjust, C = Clean, I = Inspect, L = Lubricate, R = Replace
!
Units of measure in the PM Interval column: Metric: 1,000 meters, Feet: 1,000 feet

2.1.1 MAIN MACHINE (B286)

Description
Scanner
Original Feed Rollers
Original Exit Rollers
Platen Plate
Original Width, Set,
Registration, Exit Sensors
Exposure Glass
CIS Surfaces
Development
Developer (1,000 g)
Development Filter
Development Roller Gear
Development Lower Casing
SM
PM Interval
Q'ty
Metric
Feet
5.5
18.0
5.5
18.0
5.5
18.0
33.0
108.0
5.5
18.0
5.5
18.0
2
27.5
90.0
5.5
18.0
5.5
18.0
5.5
18.0
2-1
PM
Comments
C
Damp cloth
C
C
C
Blower brush
C
Damp cloth or glass
cleaner
C
Alcohol or lens paper
R
Replace if necessary.
C
Dry cloth or vacuum
cleaner
I
C
Dry
B286/B289
PM Table