Scanner
6.2.3 ORIGINAL WIDTH DETECTION
Multiple sensors are used to detect the width of the original when it is set on the original
table:
!
Metric. 10 sensors: 9 original width sensors and the original set sensor [1] which also
functions as a width sensor. Sensor [2] above is not in the EU machine.
!
Inch. 11 sensors: 10 original width sensors and the original set sensor [1] which also
functions as a width sensor. Sensor [2] (30") above is included in the NA machine.
B286/B289
6-10
SM