[0 to 100/1 sec.]
RCG Read Timeout
10 Sets the length of time (seconds) for the timeout when sent data is written from
the RCG during a call over the @Remote network.
[0 to 100/1 sec.]
Port 80 Enable
Controls if permission is given to get access to the SOAP method over Port 80
on the @Remote network.
11
[0 to 1/1]
0: No. Access denied
1: Yes. Access granted.
@Remote Communication Permission Setting DFU
NVRAM Offset: NrsCommEnable
12
[0 to 1/1/1]
0: Disable
1: Enable
RCG – C Registed
21 This SP displays the Embedded RC Gate installation end flag.
1: Installation completed
2: Installation not completed
RCG – C Registed Detail
This SP displays the Embedded RC Gate installation status.
22
0: Basil not registered
1: Basil registered
2: Device registered
Connect Type (N/M)
23 This SP displays and selects the Embedded RC Gate connection method.
0: Internet connection
1: Dial-up connection
SM