Ricoh B286 Service Manual page 452

Table of Contents

Advertisement

SP6-xxx Peripherals
This SP modifies the operation of the fan fold sensor (R) to determine the lengths
of the odd and even sections for long fan folding) including file flap folding).
!
If the first fold is a peak fold, this SP setting determines the length even
number sections.
!
If the first fold is a valley fold, this SP setting determines the length of odd
sections, excluding the 1
Note: Adjustment in the "-" or "+" direction decreases or increases the length.
45 Fold Length: 1
This SP fine adjusts the length of the sections between folds for copies printed on
A3 SEF paper.
[-20 to +20/0/0.1]
Note: Adjustment in the "-" or "+" direction decreases or increases the length.
51 Margin Fold Length: File
This SP fine adjusts the calculated length of the file flap.
[-20 to +20/0/0.1]
61 Margin Fold Length: Threshold
This SP adjusts the threshold variable that the machine uses to calculate when to
do adjusted folding.
[-70 to +70/0/0.1]
91 Regular Size Fold Switching
This SP determines whether the lengths of the sections can be adjusted for
folding standard paper sizes.
[0 to 1/0/1]
0: Adjustment allowed
1: Adjustment not allowed
6965
Pre-Fold Adjustment (Corner Folder) Not Used
B286/B289
st
section.
st
Fold Peak: A3 SEF
5-182