4974
CIS Power Corr DFU
These SP's adjust the level of current to the CIS elements. Adjusting these
settings affect LED control. Adjustments can be done separately for Red, Green,
and Blue.
Corrects the current level for Red. When set to "0", the LED is off. When
1 R
set to any value other than "0", the LED lights and Red can be adjusted.
[+127 to -127/0/1]
Corrects the current level for Green. This SP is adjusted to change when
the scanning with the default settings does not achieve satisfactory
11 G
results.
[+127 to -127/0/1]
Corrects the current level for Blue. When set to "0", the LED is off. When
21 B
set to any value other than "0", the LED lights and Blue can be adjusted.
[+127 to -127/0/1]
4975
Original Edge Hold
This SP determines whether the machine stops and holds the original after the
original is fed so that it does not fall.
[0 to 1/0/1]
*0: Disable, 1: Enable