3.2.2 ORIGINAL FEED UNIT ROLLERS

1.
Lift and lock the scanner unit. (See section 3.1.7 "Raising and Locking the Scanner
Unit")
2.
Original width sensor cover [A]
3.
Original exit roller cover (" x 2) [B]
Original exit rollers ($ x 1, bushings x 2, hex "x1) [C]
4.
5.
Original feed rollers ($ x 2, bushings x 2) [D]
Reinstallation
!
After you replace the original feed roller or the original exit roller, do the CIS sub scan
test and adjustment as follows.
1.
Do SP2902-2 (IPU Test Pattern) and print Pattern 11.
2.
Make a copy of the Pattern 11 output that you made in step 1.
3.
On the copy, first, check Area "B."
SM
3-11