1947
Press FB Stop: Time Period
This SP sets the length of time that pressure roller feedback is suspended for the
paper lengths defined by SP1945.
!
Pressure roller feedback control begins when the time set with this SP has
elapsed after paper feed starts.
!
As more paper is fed for a multiple print job, the time setting for succeeding
sheets is overwritten.
!
However, for succeeding sheets where the time prescribed for feedback
suspension is "0", the "0" value is not overwritten, but feedback suspension
control is maintained until countdown for the multiple copies is finished.
1 Length Level 1: Normal
2 Length Level 2: Normal
3 Length Level 3: Normal
4 Length Level 4: Normal
5 Length Level 5: Normal
11 Length Level 1: Cold Start
12 Length Level 2: Cold Start
13 Length Level 3: Cold Start
14 Length Level 4: Cold Start
15 Length Level 5: Cold Start
16 Length Level 0: Cold Start
Normally, pressure roller feedback control does not operate when the paper
length is not prescribed (length = 0). But if copying was started while feedback
control was not operating, during a cold start for example, then feedback control
operates using the setting of this SP code.
[0 to 300/15/1 sec.]
SM
[0 to 300/15/1 sec.]
[0 to 300/30/1 sec.]
[0 to 300/45/1 sec.]
[0 to 300/60/1 sec.]
[0 to 300/80/1 sec.]
[0 to 300/20/1 sec.]
[0 to 300/35/1 sec.]
[0 to 300/50/1 sec.]
[0 to 300/70/1 sec.]
[0 to 300/100/1 sec.]