Fusing Temperature Control: Temperature Feedback During - Ricoh B286 Service Manual

Table of Contents

Advertisement

Fusing Unit
Note:
If the target pressure roller temperature is set for 65°C, inching with rotation of the pressure
roller and hot roller starts, then the copy ready temperature is set when both temperatures
at
and
are reached.
!
Inching Start Temperature =
!
Pressure roller target temperature for inching control:
Fusing Temperature Control: Temperature Feedback During Copying
This machine uses the feedback of the hot roller thermistor and two pressure roller
thermistors, one at the center and one at the end of the pressure roller, to control the fusing
temperature. The SP codes settings shown in the tables and illustrations below determine
how fusing temperature is controlled for the paper thickness modes (Mode 1 to 5) for each
type of paper.
Here is a quick summary of the SP codes that are used to maintain optimum fusing
temperature.
!
These SP codes are set at the factory and normally should not require adjustment
in the field.
1931
Target Temp: Hot Roller
1932
Target Temp: Press Roller
1934
Lower Limit Temp: Hot Roller
1935
Pressure FB Control Steps
Press FB Ctrl Switch by Temp
1941
Diff
B286/B289
SP1937-3
Sets the target temperature of the hot roller.
Sets the target temperature of the pressure
roller
Sets the minimum difference in temperature
allowed between the actual temperature and
the target temperature of the hot roller
Changes the stepped adjustments of SP1932
(Target Temp: Pressure Roller) by using the
sum of the settings of SP1932 (Target Temp:
Pressure Roller) +SP1935 (Press FB Control
Steps).
Sets the temperature differential that
determines when the machine switches to the
supplement mode for pressure roller feedback
control. (See description below.)
6-74
SP1948
SM

Advertisement