Main Machine Installation (B286)
3.
Open the upper unit.
4.
Push the cleaning-blade release lever [1] to the right.
!
The cleaning-blade release lever keeps the cleaning blade away from the
drum during transportation. To prevent damage to the drum, before you move
the main machine to a different location, be sure to push this lever to the left.
5.
Close the upper unit.
6.
Do SP3001-2 to initialize the ID sensor again. Initialization takes about 15 sec.
!
The ID sensor must be initialized again after the cleaning blade has been
lowered onto the drum.
7.
Exit the SP mode and turn off the main power switch.
8.
If you will install one or more of the following options, do these installations at this time:
Roll Feeder, Paper Cassette See section 1.4 "Roll Feeder (B851/B852)", section
!
1.5 "Paper Cassette (B853)"
!
Table: See section 1.6 "Table (B854)"
!
MFP Options. See section 1.10 "Installation of MFP Options."
!
After installing all options (other than the folder unit/manual feeder), complete
main machine installation. See section 1.2.3 "Main Machine Final Installation."
!
Folder Unit, Manual Feed. See section 1.7 "Folder Unit (B889)", section 1.9
"Manual Feeder (D333)."
!
The Folder Unit and Manual Feed Unit must be installed after the main
machine has been completely installed and leveled.