Machine Setup Menu Table - MIMAKI TS300P-1800 Operation Manual

Hide thumbs Also See for TS300P-1800:
Table of Contents

Advertisement

Chapter 3 Mchine setting

MACHINE SETUP MENU table

Function name
AUTO Power-off (
P.3-16)
TAKE-UP UNIT
TAKE-UP UNIT
TAKE-UP
(
P.3-16)
TENSION BAR
TAKE-UP SW
ON
Top blower
(
P.3-16)
OFF
MEDIA REMAIN (
P.3-17)
HEAD HEIGHT (
P.2-4)
PG DROP ADJUST (
DETECTION TYPE AUTO/MANUAL
MEDIA DETECT
INPUT
(
P.3-18)
THICKNESS
DRYING FEED
DRYING FEED
(
P.3-18)
BACKWARD FEED ON/ OFF
LANGUAGE (
P.3-18)
TIME (
P.3-18)
UNIT/ TEMP. (
P.3-18)
UNIT/ LENGTH (
P.3-18)
KEY BUZZER (
P.3-19)
CONFIRM. FEED (
P.3-19)
SPACE FEED MODE (
Set the network.
Check IP Addr.
Check MAC Addr.
DHCP
NETWORK
(
P.3-20)
AutoIP
IP Address
Default Gateway
DNS Address
SubNet Mask
3-14
Set value
NONE/
10 ~ 600min
ON/ OFF
ON/ OFF
Continuance/ Temporary
AUTO/ STORONG/ WEAK
ON/ OFF
2.0 to 7.0 mm
P.3-17)
ON/ OFF
OFF/ 100 to 1000mm
+4h ~ -20h
°C (Centigrade)/°F (Fahrenheit) °C
mm / inch
OFF / ON
ON / OFF
INTERMITTENT /
P.3-19)
CONTINUOUS
The IP address currently used by this machine is displayed.
The IP address currently used by this machine is displayed.
ON / OFF
ON / OFF
*1
Set the IP address used by this machine.
*1
Set the default gateway used by this machine.
*1
Set the DNS server address used by this machine.
*1
Set the digit number of the subnet mask used by this machine.
Default
Meaning
When no operation has been performed for the
30min
set time, the power supply is automatically
turned "OFF".
For setting whether the take-up unit is used or
ON
not used.
For setting whether the take-up tension bar is
OFF
used or not used.
Continua
Set the operation method when press ON / OFF
nce
button on the take-up unit.
AUTO
Set the operation of the top blower in print.
OFF
You can control the remaining amount of media.
Set the head height.
Adjust the outward and return ink drop positions
during bidirectional printing.
AUTO
Set the media detection method.
Set whether to enter the thickness of the media
ON
to be used during media detection.
Set the length of the media to feed after printing
OFF
is complete.
OFF
Set if require the back-feed after feed.
English
Displayed language is changed.
Japan time
Time difference is corrected.
A unit for displaying temperature is set.
mm
A unit for displaying length and area is set.
ON
A buzzer sound when keys are pressed is set.
Set whether media feeding is performed for
ON
checking the result of the test printing etc. or not.
INTERMI
Change the feed mode of the margin included in
TTENT
the image data.
When it is ON, the IP address given by the
DHCP server is used.
When it is ON, the IP address is determined by
the AutoIP protocol. However, DHCP is ON,
DHCP has priority.