ERROR 656
NCU SN ADJST
ERROR 657
REPLACE NCU INK PAD
ERROR 658
NCU SENSOR LV LOW
ERROR 65b
NCU Sens Adj Err H
ERROR 65c
NCU Sens Adj Err L
ERROR 702
THERMISTOR CONNECT
ERROR 710
HEATER TEMP ERROR
ERROR 71b
FAN HEATER ERROR
ERROR 901
INVAILD OPERATION
ERROR 902
DATA REMAIN
ERROR 90d
NO HEAD SELECT
ERROR 90f
PRINT AREA SHORT
ERROR 91a
ADJUST HEAD HEIGHT
Cause
Sensor sensitivity adjustment has failed.
The NCU ink pat is full.
THE sensitivity level of the NCU sensor
is low.
The sensitivity level of the sensor cannot
be adjusted.
The thermistor connection of a heater is
defective.
The temperature abnormality of the
heater has been detected.
When this error occurred and if the tem-
perature abnormality cannot be
resolved, the power supply of the
machine is forcibly turned off.
Power of optional drying heater is not
turned on.
Detect abnormal temperature of the
optional drying heater.
Connection of the optional drying heater
can not be confirmed.
Cover of the optional drying heater is
open.
Due to a certain error, the function can-
not be performed.
There remains received data that has
not yet been printed.
An error occurred in the mounted heads.
The media width or the media length
required for printing is not enough.
The head height setting saved in the
machine and the current head height do
not match.
Chapter5 Troubleshooting
Solution
• Check the state of the nozzles, and if there
are frequent nozzle missing and ink droplet
misalignment, conduct cleaning to restore.
• If the same error message still appears after
restoring the state of the nozzles, contact
our service desk or your local distributor to
call for service.
• Contact our service desk or your local dis-
tributor to call for service.
• Replacement of the NCU is recommended.
Contact our service desk or your local dis-
tributor to call for service.
• Turn off the main power to the machine and
turn it on after a while.
• If the same error message appears again,
contact your local distributor to call for ser-
vice.
• Turn off the main power to the machine and
turn it on after a while.
• If the same error message appears again,
contact your local distributor to call for ser-
vice.
• Please make sure this unit and the optional
heater is properly connected.
• Return to the local screen, check the error
status and take a countermeasure.
• Execute the data clear function. (
• Turn off the main power to the machine and
turn it on after a while.
• If the same error message appears again,
contact your local distributor to call for ser-
vice.
• Change the media to the one with enough
width or length.
• When the media width narrows because the
origin moved, slide the origin to the right to
widen the effective media width.
• Set the head height. (
P.2-4)
1
2
2
2
P.2-19)
5
6
5-11