MIMAKI TS300P-1800 Operation Manual page 39

Hide thumbs Also See for TS300P-1800:
Table of Contents

Advertisement

Installing the counter weight for
adjusting the tension-bar weight (1)
• If the large / small two types of
counter weight (large (100g x
4 sheets) / small (50g x 20
sheets)) are attached, install a
counter weight in the following
manner.
• Check the tension of the
media and attach an
appropriate number of
weights.
Install the proper number of the counter weight depending
on the media type.
You can attach the counter weight up to 12 (Large : 2,
Small : 10) each for right and left.
Media condition
Ruck is generated in the
The tension applied on the
media feeding direction.
media is too strong.
Remove the weight, and lighten
The media skews at printing.
the tension bar.
The media sags and the
The tension applied on the
machine cannot take it up
media is too weak.
beautifully.
Attach the weight, and make the
The media floats on the
tension bar heavier.
platen.
Counter weight
Do not remove the weight that
was originally attached.
Also, do not remove the
screws retaining the weight.
Small
Large
Solution
Chapter 2 Basic Operation
Number of counter weights you can attach
• The number of counter weights you can attach
differs depending on the outer diameter after
taking up the media.
• Instead of the torque limiter attached to the printer
take-up device, you can attach the motor direct-
connection unit supplied with the AMF kit.
In this case, the number of counter weights
attached to the tension bar differs.
For torque limiter
Roll outside
Winding
Maximum number
*1
diameter
direction
Wound inward
12 (Large x 2 + Small x 10)
Φ80mm
Wound outward 12 (Large x 2 + Small x 10)
Wound inward
12 (Large x 2 + Small x 10)
Φ150mm
Wound outward
4 (Large x 0 + Small x 4)
Wound inward
6 (Large x 0 + Small x 6)
Φ250mm
Wound outward
*1. When using media with the diameter that is out
of the range specified above, see the table
below and check the maximum number.
:Wound outward
:Wound inward
Roll outside diameter
For motor direct-connection unit
Roll outside
Winding
Maximum number
*1
diameter
direction
Φ150mm
12 (Large x 2 + Small x 10)
Φ250mm
6 (Large x 0 + Small x 6)
*1. When using media with the diameter that is out
of the range specified above, see the table
below and check the maximum number.
:Wound outward
:Wound inward
Roll outside diameter
• Do not attach more than the maximum number of
counter weights.
• Not to lose the unused counter weight, put it in the
storage box.
0
2
2
2
5
6
2-11

Hide quick links:

Advertisement

Table of Contents
loading