Chapter 2 Basic Operation
Using the tension bar to set the roll
media
When setting media, read the following notes carefully.
Set the take-up tension bar to "ON" in
1
"Setting Take-up unit" of the machine
setup.(
P.3-16)
Perform Steps 1 to 12 for "Setting a roll
2
media".
Close the front cover.
3
With switches of the take-up device, roll up
4
the media about once.
Direction selector
(1) Set the take-up direction using the direction
selector switch on the left, turn the ON/OFF
button on the right to ON, and then take up
the media.
(2) Just before the media stretched tight, turn
the right ON/OFF button to OFF to stop.
Press
to select "ROLL" .
5
• Detects the media width.
• When [MEDIA DETECT] of the machine setup is
"MANUAL" (
the manual media width setting" and enter the
media width.
• When [MEDIA RESIDUAL] of the machine setting
is "ON" (
media remaining amount is displayed after
detecting the media width.(
2-8
Front cover
ON/ OFF button
switch
P.3-17), refer to P.2-9 "Setting of
P.3-17), the screen for entering
P.2-9)
Secure the media on the take-up device.
6
(
P.2-10)
(1) Feed the media up to the core of the roll
media of the take-up device by pressing [] .
(2) Fix the middle of the media with adhesive
tape.
(3) In the same manner, fix the left side and right
side of the media.
• Make sure that the there is no slack or
wrinkle on the media in such condition that
the roll media is pulled to right and left evenly,
and then stick the tape.
After displaying "Detect Take-up unit",
7
press
and then select "START".
• When the media is set inward, feed the media for
approximately 110 mm after this.
Lift the tension- bar down slowly.
8
• Unlock the tension-bar, and then lift it down.
• The tension bar is initialized.
Once initialization is successful, the printer starts
the winding diameter detection. When winding
diameter detection is complete, the local screen is
displayed.
• If initialization fails,"Detect failure" is displayed.
Return the tension bar to the standby position.
• If detection fails and you want to start detection
again, raise and lower the clamp lever, and
perform the operation from step 5.