Chapter 3 Mchine setting

Setting a AUTO Power-off

When no operation has been performed for the set time,
the power supply is automatically turned "OFF".
Press
1
in LOCAL.
• MACHINE SETUP MENU will be displayed.
Press
2
OFF", and press the
Press
3
press the
• Set Value : none, 10 to 600min
Press the
4
end the setting.

Setting Take-up unit

For the "TAKE-UP UNIT" settings, set the following items:
• Use take-up unit/ Do not use take-up unit.
• Use/Do not use the take-up tension bar.
• Operation when the ON/OFF switch for take-up unit is
pressed.
Press
1
in LOCAL.
• MACHINE SETUP MENU will be displayed.
Press
2
and press the
Press the
3
• "TAKE-UP UNIT" will be selected.
Press
4
press the
• Set Value : ON/ OFF
Press
, and press the
5
• "TAKE-UP TENSION BAR" will be selected.
Press
6
press the
• Set Value : ON/ OFF
Press
, and press the
7
• "TAKE-UP SW" will be selected.
3-16
(MENU)
(twice)
to select "AUTO POWER
key.
to select a set value, and
key.
key several times to
(MENU)
(twice)
to select "TAKE-UP UNIT",
key.
key.
to select a set value, and
key.
key.
to select a set value, and
key.
key.
Press
to select a set value, and
8
press the
• Set Value : Continuance/ Temporary
Continuance :
Switching ON / OFF the winding operation when
pressing the switch each time. (Take-up unit in
operation does not stop until press again ON /
OFF switch.)
Temporary :
Do the winding operation only while holding
down the switch. (When release the switch,
winding operation is stopped. )
• If you are using a direct-connection unit, even set
to "Continuance", it will automatically run the
"Temporary" operation.
Press the
9
end the setting.

Setting Top Blower

Set the operation of the top blower in print.
Turn the top blower setting "ON", and you can set the
strength for the blower.
Press
(MENU)
1
in LOCAL.
• MACHINE SETUP MENU will be displayed.
Press
to select "Top blower",
2
and press the
Press
to select "ON", and press
3
the
key.
ON : You can choose the air volume of the blower.
OFF : The top blower does not work while printing
process. Proceed to step 6.
Press
to select "STRENGTH",
4
and press the
Press
to select a set value
5
(AUTO/ STRONG/ WEAK), and press the
key.
• Set value : ON/ OFF
Press the
6
end the setting.
key.
key several times to
(twice)
key.
key.
key several times to

Hide quick links: