Chapter5 Troubleshooting
Message
ERROR 18e
FLS NOT COMP
ERROR 18f
OFFSET START
ERROR 18f
OFFSET END
ERROR 1d9
Main PCB V48-1
ERROR 1ce
SLIDER PCB V24
ERROR 1cf
SLIDER PCB V1R8
ERROR 1de
SLIDER PCB V1R2
ERROR 1df
SLIDER PCB V2R5
ERROR 1e0
SLIDER PCB V3R3
ERROR 1e1
SLIDER PCB V5
ERROR 1e2
SLIDER PCB V48
ERROR 1db
Station4 PCB V48
ERROR 1dc
Station4 PCB V24
ERROR 1dd
Station4 PCB V24-A
ERROR 1e6
PRAM SIZE SHORTAGE
ERROR 201
COMMAND ERROR
ERROR 202
PARAMETER ERROR
ERROR 206
PRINTING MODE
5-8
Cause
An error was detected in the waveform
being printed.
An error was detected in the waveform
being printed.
An error occurred in the main PCB .
An error occurred in the power supply of
the slider PCB.
An error occurred in the power supply of
the Station IV PCB.
The memory size is insufficient.
The machine received some data other
than print data.
Or, an error occurred in the transmitted
print data.
An error occurred in the transmitted print
data.
Unable to print with the printing condi-
tions of the print data received.
Solution
• Turn off the power to the machine and turn it
on after a while.
• If the same error message appears again,
contact your local distributor to call for ser-
vice.
• Securely connect the interface cable in posi-
tion.
• Use an interface cable conforming to the
specifications.
• Check the output conditions of the print data
in the RIP software.
• Check the profile.
• If the same error message appears again,
contact your local distributor to call for ser-
vice.