Setting of VacuumFan

Sets the absorbability of the media.
By setting the absorption power to match the media, you
can prevent print errors due to media rise-up.
Press
(MENU)
1
Press
to select SETUP 1 to 4,
2
and press the
• SETUP MENU will be displayed.
Press
(>>) .
3
Press
to select "VACUUM FAN",
4
and press the
Press
to select a set value, and
5
press the
• Set value : HOST/WEAK /STANDARD/ STRONG
press the
6
end the setting.

Setting of Feed Speed

Changes the media feeding speed in printing.
Press
(MENU)
1
Press
to select SETUP 1 to 4,
2
and press the
• SETUP MENU will be displayed.
Press
(>>) twice.
3
Press
to select ""FEED SPEED",
4
and press the
Press
to select a set value, and
5
press the
• Set value : HOST / 10 to 200%
Press the
6
end the setting.
• Some speed is not changed according to a setting
condition.
• The media feed speed during printing is decided
by this setting and the set value in [Setting of Feed
Quality].
in LOCAL.
key.
key.
key.
key several times to
in LOCAL.
key.
key.
key.
key several times to

Setting of Feed Quality

Change the speed and acceleration to feed a media
during printing. If the media feed is not stable, change the
setting into [QUALITY] may improve the situation.
Action will be changed as follows according to a setting.
• STANDARD : The media feed is done with the default value
of the speed and acceleration.
• QUALITY
: The media feed is done with the speed and
acceleration slower than the default setting
value.
Press
(MENU)
1
Press
to select SETUP 1 to 4,
2
and press the
• SETUP MENU will be displayed.
Press
(>>) twice.
3
Press
to select "FEED
4
QUALITY", and press the
Press
to select a set value, and
5
press the
• Set value : HOST / STANDARD / QUALITY
press the
6
end the setting.
• The media feed speed during printing is decided
by this setting and the set value in [Setting of Feed
Speed].