15
15.6

Features

15.6.1
General settings
Parameter
Number of measuring points
Distances
15.6.2
Measuring point filter
Parameter
Measuring point filter
Error limit
Confidence interval (±xσ)
Minimum % proportion of
retained points
330
Explanation
Specifies whether the number of measuring points is fixed or
freely selectable for each feature
Settings:
Free: Number of measuring points is freely selectable
Fixed: Number of measuring points is fixed
Default setting: Free
Display of the measuring point distance
Settings:
Signed: Distances are displayed with a positive or negative
algebraic sign, depending on the relative direction
Absolute: Distances are displayed without an algebraic sign,
independently of the relative direction
Default setting: Signed
Explanation
Automatic compensation of the measuring point acquisition for
detecting measuring points outside the normal distribution
Settings: ON or OFF
Default setting: ON
Definition of the maximum permissible deviations of the measur-
ing point filter
Setting range: ≥ 0 (Millimeters or Inch)
Default setting: 0.003 mm or 0.0001181"
Definition of the measuring point filter range
Setting range: 0 ... 10
Default value: 2
Percentage of the measuring points that are used for the calcula-
tion of the feature
Setting range: 0 % ... 100 %
Default value: 75 %