CALIBRATION MENU { CONTROL CALIBRATION ADJUSTMENT }
The steps required to calibrate the operation of the Steering Wheel, Throttle Trigger and Auxiliary Lever are the same. The
example shown in this section details calibrating the Steering Wheel.
Two Calibration Options are available:
FACTORY - When selected, control End Points and Neutral positions are set to the original Factory Default Calibration values.
This option should be used if there is a problem with the User Calibration values or you want to restore the Factory Default
Calibration values.
USER - When selected, the user manually calibrates the control End Points and Neutral positions. This option should be
used in most all cases as part of a routine maintenance schedule or if you've limited or otherwise adjusted the travel of the
Steering Wheel.

Calibrating the Steering, Throttle and Auxiliary Lever Controls:

1) From within the SYSTEM menu, scroll UP or DOWN to highlight the CALIBRATION
menu.
2) Press the ENTER key to open the CALIBRATION menu. The ST (Steering)
menu will be highlighted.
If you want to calibrate a different control, scroll UP or DOWN to highlight
the control option you would like to calibrate, either TH (Throttle) or
LEVER (Auxiliary Lever).
3) Press the ENTER key to open the ST VR CALIBRATION menu (or the TH VR
CALIBRATION menu or the LEVER VR CALIBRATION menu, depending on
your selection in step 2). SETTING > FACTORY will be highlighted.
4) Press the ENTER key, then scroll UP or DOWN to highlight SETTING > USER.
Calibration value information specific to the control you're calibrating will be
displayed. If you're calibrating the Steering Wheel, NEUT > LEFT and RIGHT
values will be displayed. If you're calibrating the Throttle Trigger, NEUT > HIGH
and BRAKE values will be displayed and if you're calibrating the Auxiliary Lever,
NEUT > HIGH and LOW values will be displayed.
IMPORTANT: When completing the steps below, do not complete the steps out of order or the calibration process may not
work correctly.
5) To calibrate the control's Neutral Point, scroll DOWN to highlight NEUT > 0.
Depending on the current state of calibration, a value other than 0 may be
displayed.
6) With the Steering Wheel (or Throttle Trigger or Auxiliary Lever) centered, press the ENTER key. NEUT > 0 OK will be displayed.
Telemetry System with Sanwa Synchronized Link Support