2.10.3

Transport and Storage

The frequency inverters must be transported and stored in an appropriate way. During transport
and storage the devices must remain in their original packaging.
The units may only be stored in dry rooms which are protected against dust and moisture and are
exposed to small temperature deviations only. The requirements of DIN EN 60721-3-1 for storage,
DIN EN 60721-3-2 for transport and labeling on the packaging must be met.
The duration of storage without connection to the permissible nominal voltage may not exceed
one year.
2.10.4

Handling and installation

Do not commission any damaged or destroyed components.
Prevent any mechanical overloading of the frequency inverter. Do not bend any components and
never change the isolation distances.
Do not touch any electronic construction elements and contacts. The frequency inverter is
equipped with components which are sensitive to electrostatic energy and can be damaged if
handled improperly. Any use of damaged or destroyed components will endanger the ma-
chine/plant safety and shall be considered as a non-compliance with the applicable standards.
Only install the frequency inverter in a suitable operating environment. The frequency inverter is
exclusively designed for installation in industrial environments.
If seals are removed from the case, this can result in the warranty becoming null and void.
2.10.5

Electrical connections

The five safety rules must be complied with.
Never touch live terminals. The DC link may have dangerous voltage levels even up to three
minutes after shutdown.
When performing any work on/with the frequency inverter, always comply with the applicable
national and international regulations/laws on work on electrical equipment/plants of the country
in which the frequency inverter is used.
The cables connected to the frequency inverters may not be subjected to high-voltage insulation
tests unless appropriate circuitry measures are taken before.
Only connect the frequency inverter to suitable supply mains.
2.10.5.1 The five safety rules
When working on/in electrical plants, always follow the five safety rules:
1. Isolate
2. Take appropriate measures to prevent re-connection
3. Check isolation
4. Earth and short-circuit
5. Cover or shield neighboring live parts.
2.10.6

Safe operation

During operation of the frequency inverter, always comply with the applicable national and inter-
national regulations/laws on work on electrical equipment/plants.
Before commissioning and the start of the operation, make sure to fix all covers and check the
terminals. Check the additional monitoring and protective devices according to the applicable na-
tional and international safety directives.
During operation, never open the machine/plant
Do not connect/disconnect any components/equipment during operation.
The machine/plant holds high voltage levels during operation, is equipped with rotating parts
(fan) and has hot surfaces. Any unauthorized removal of covers, improper use, wrong installation
or operation may result in serious injuries or material damage.
10/13